ON-THE-FLY FLUORESCENCE LIFETIME DETECTION IN HPLC USING A MULTIHARMONIC FOURIER-TRANSFORM PHASE-MODULATION SPECTROFLUOROMETER

被引:40
作者
SMALLEY, MB [1 ]
SHAVER, JM [1 ]
MCGOWN, LB [1 ]
机构
[1] DUKE UNIV,DEPT CHEM,PAUL M GROSS CHEM LAB,DURHAM,NC 27706
关键词
D O I
10.1021/ac00071a022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Frequency-domain fluorescence lifetime detection has been demonstrated recently as a technique for detecting and resolving overlapping peaks on-the-fly in reversed-phase high-performance liquid chromatography (RP-HPLC). However, instrument limitations necessitate multiple injections of the same sample for peak resolution. The introduction of a commercially available multiharmonic Fourier transform spectrofluorometer (MHF) eliminates this problem and offers other advantages as well. The MHF data acquired on-the-fly during a single chromatographic run contain all of the multifrequency information needed to determine lifetimes and to indicate and resolve overlapping peaks at intervals as short as several milliseconds. This allows essentially continuous monitoring of both lifetime and intensity during chromatographic elution. This approach to the addition of lifetime in fluorescence detection increases the information content of chromatographic-based analysis without increasing the time per analysis. This paper presents the first results obtained using MHF detection, including measurements of single components and simple mixtures. Optimization of instrumental and experimental conditions is discussed, including the nature of the raw data and the procedures that were developed to extract and process the necessary lifetime and intensity information.
引用
收藏
页码:3466 / 3472
页数:7
相关论文
共 13 条
[1]   THE USE OF ISOCHRONAL REFERENCE-STANDARDS IN PHASE AND MODULATION FLUORESCENCE LIFETIME MEASUREMENTS [J].
BARROW, DA ;
LENTZ, BR .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1983, 7 (03) :217-234
[2]   MULTIFREQUENCY PHASE-MODULATION FLUORESCENCE LIFETIME DETERMINATIONS ON-THE-FLY IN HPLC [J].
COBB, WT ;
MCGOWN, LB .
APPLIED SPECTROSCOPY, 1989, 43 (08) :1363-1367
[3]   PHASE-MODULATION FLUOROMETRY FOR ONLINE LIQUID-CHROMATOGRAPHIC DETECTION AND ANALYSIS OF MIXTURES OF BENZO(K)FLUORANTHENE AND BENZO(B)FLUORANTHENE [J].
COBB, WT ;
MCGOWN, LB .
APPLIED SPECTROSCOPY, 1987, 41 (08) :1275-1279
[4]   ONLINE FLUORESCENCE LIFETIME DETECTION FOR CHROMATOGRAPHIC PEAK RESOLUTION [J].
COBB, WT ;
MCGOWN, LB .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :186-189
[5]   MEASUREMENT OF FLUORESCENCE LIFETIMES DURING LIQUID-CHROMATOGRAPHY [J].
DESILETS, DJ ;
KISSINGER, PT ;
LYTLE, FE .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1830-1834
[6]  
DOBB WT, 1988, ASTM STP, V1009, P12
[7]   TIME-RESOLVED FLUOROMETRY IN DETECTION OF ULTRATRACE POLYCYCLIC AROMATIC-HYDROCARBONS IN LAKE WATERS BY LIQUID-CHROMATOGRAPHY [J].
FURUTA, N ;
OTSUKI, A .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2407-2413
[8]   TIME-RESOLVED FLUORIMETRY WITH A SUBNANOSECOND DYE-LASER SOURCE FOR THE DETERMINATION OF POLYNUCLEAR AROMATIC-HYDROCARBONS AFTER SEPARATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMASAKA, T ;
ISHIBASHI, K ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1982, 142 (OCT) :1-12
[9]   3-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BASED ON TIME-RESOLVED LASER FLUORIMETRY [J].
ISHIBASHI, K ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1985, 173 (JUL) :165-175
[10]  
KALOWICZ JR, 1983, PRINCIPLES FLUORESCE