EDGE-DETECTION VERSUS DENSITOMETRY FOR ASSESSING CORONARY STENTING QUANTITATIVELY

被引:31
作者
STRAUSS, BH
JUILLIERE, Y
RENSING, BJ
REIBER, JHC
SERRUYS, PW
机构
[1] ERASMUS UNIV,THORAXCTR,CATHETERIZAT LAB,POB 1738,3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV,THORAXCTR,CLIN & EXPTL IMAGE PROC LAB,3000 DR ROTTERDAM,NETHERLANDS
关键词
D O I
10.1016/0002-9149(91)90008-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The optimal method used to analyze quantitatively the immediate angiographic results of coronary stenting in the coronary arteries has not been studied. Accordingly, minimal luminal cross-sectional area was determined by 2 methods, edge detection and densitometry, in 19 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) and then coronary stent implantation for symptomatic coronary stenoses. The correlation coefficient, 0.73 before angioplasty, decreased to 0.59 after coronary angioplasty and then increased to 0.83 after stent implantation. The mean differences between edge detection and densitometric determinations of minimal luminal cross-sectional area were 0.31 +/- 0.51 mm2 before PTCA, -0.38 +/- 1.22 mm2 after angioplasty and 0.35 +/- 0.79 mm2 after coronary stenting. It is concluded that, although the correlation and variability in the measurement of minimal luminal cross-sectional area between edge detection and densitometry deteriorate after PTCA, they are improved after stenting, probably because of smoothing of the vessel contours by the stent and remodeling of the stented segment into a more circular configuration. Therefore, in the stented coronary artery, edge detection and densitometry are equally acceptable methods of analysis.
引用
收藏
页码:484 / 490
页数:7
相关论文
共 20 条
[11]  
Reiber JHC, 1986, QUANTITATIVE CORONAR
[12]   THE DISEASE-FREE WALL IN CORONARY ATHEROSCLEROSIS - ITS RELATION TO DEGREE OF OBSTRUCTION [J].
SANER, HE ;
GOBEL, FL ;
SALOMONOWITZ, E ;
ERLIEN, DA ;
EDWARDS, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (05) :1096-1099
[13]   ADDITIONAL IMPROVEMENT OF STENOSIS GEOMETRY IN HUMAN CORONARY-ARTERIES BY STENTING AFTER BALLOON DILATATION [J].
SERRUYS, PW ;
JULLIERE, Y ;
BERTRAND, ME ;
PUEL, J ;
RICKARDS, AF ;
SIGWART, U .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (14) :G71-G76
[14]   ASSESSMENT OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY BY QUANTITATIVE CORONARY ANGIOGRAPHY - DIAMETER VERSUS DENSITOMETRIC AREA MEASUREMENTS [J].
SERRUYS, PW ;
REIBER, JHC ;
WIJNS, W ;
VANDERBRAND, M ;
KOOIJMAN, CJ ;
TENKATEN, HJ ;
HUGENHOLTZ, PG .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (06) :482-488
[15]   INTRAVASCULAR STENTS TO PREVENT OCCLUSION AND RESTENOSIS AFTER TRANS-LUMINAL ANGIOPLASTY [J].
SIGWART, U ;
PUEL, J ;
MIRKOVITCH, V ;
JOFFRE, F ;
KAPPENBERGER, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (12) :701-706
[16]   CAN THE IMMEDIATE EFFICACY OF CORONARY ANGIOPLASTY BE ADEQUATELY ASSESSED [J].
SMALLING, RW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (02) :261-263
[17]   VIDEODENSITOMETRIC DETERMINATION OF MINIMUM CORONARY-ARTERY LUMINAL DIAMETER BEFORE AND AFTER ANGIOPLASTY [J].
TOBIS, J ;
NALCIOGLU, O ;
JOHNSTON, WD ;
QU, L ;
REESE, T ;
SATO, D ;
ROECK, W ;
MONTELLI, S ;
HENRY, WL .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (01) :38-44
[18]   ACCURACY AND INTEROBSERVER VARIABILITY OF CORONARY CINEANGIOGRAPHY - A COMPARISON WITH POSTMORTEM EVALUATION [J].
TRASK, N ;
CALIFF, RM ;
CONLEY, MJ ;
KONG, Y ;
PETER, R ;
LEE, KL ;
HACKEL, DB ;
WAGNER, GS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (05) :1145-1154
[19]  
VLODAVER Z, 1971, PROG CARDIOVASC DIS, V14, P156
[20]   DOES THE QUANTITATIVE ASSESSMENT OF CORONARY-ARTERY DIMENSIONS PREDICT THE PHYSIOLOGICAL SIGNIFICANCE OF A CORONARY STENOSIS [J].
ZIJLSTRA, F ;
VANOMMEREN, J ;
REIBER, JHC ;
SERRUYS, PW .
CIRCULATION, 1987, 75 (06) :1154-1161