SOFT-X-RAY MICROSCOPE USING FOURIER-TRANSFORM HOLOGRAPHY

被引:7
作者
MCNULTY, I
KIRZ, J
JACOBSEN, C
ANDERSON, E
HOWELLS, MR
RARBACK, H
机构
[1] UNIV CALIF BERKELEY LAWRENCE BERKELEY LAB,BERKELEY,CA 94720
[2] BROOKHAVEN NATL LAB,NATL SYNCHROTRON LIGHT SOURCE,UPTON,NY 11973
关键词
D O I
10.1016/0168-9002(90)90036-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Fourier transform holographic microscope with an anticipated resolution of better than 100 nm has been built. Extensive testing of the apparatus has begun. Preliminary results include the recording of interference fringes using 3.6-nm X-rays. The microscope employs a charge-coupled-device (CCD) detector array of 576 × 384 elements. The system is illuminated by soft X-rays from a high-brightness undulator. The reference point source is formed by a Fresnel zone plate with a finest outer zone width of 50 nm. Sufficient temporal coherence for hologram formation is obtained by a spherical grating monochromator. The X-ray hologram intensities at the recording plane are to be collected, digitized and reconstructed by computer. Data acquisition is under CAMAC control, while image display and off-line processing takes place on a VAX graphics workstation. Computational models of Fourier transform hologram synthesis, and reconstruction in the presence of noise, have demonstrated that numerical methods in two dimensions are feasible and that three-dimensional information is potentially recoverable. © 1990.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 16 条
[1]  
ANDERSON EH, 1989, SPIE, V1160, P2
[2]   X-RAY HOLOGRAM OBTAINED BY USING SYNCHROTRON RADIATION [J].
AOKI, S ;
ICHIHARA, Y ;
KIKUTA, S .
JAPANESE JOURNAL OF APPLIED PHYSICS, 1972, 11 (12) :1857-1857
[3]   THOMSON-CSF FRAME-TRANSFER CHARGE-COUPLED-DEVICE IMAGERS - DESIGN AND EVALUATION AT VERY LOW FLUX LEVEL [J].
BEAL, G ;
BOUCHARLAT, G ;
CHABBAL, J ;
DUPIN, JP ;
FORT, B ;
MELLIER, Y .
OPTICAL ENGINEERING, 1987, 26 (09) :902-910
[4]  
HADDAD WS, 1988, OSA P SHORT WAVELENG, V2, P284
[5]   X-RAY HOLOGRAMS AT IMPROVED RESOLUTION - A STUDY OF ZYMOGEN GRANULES [J].
HOWELLS, M ;
JACOBSEN, C ;
KIRZ, J ;
FEDER, R ;
MCQUAID, K ;
ROTHMAN, S .
SCIENCE, 1987, 238 (4826) :514-517
[6]   EXPERIMENTS IN X-RAY HOLOGRAPHIC MICROSCOPY USING SYNCHROTRON RADIATION [J].
HOWELLS, MR ;
IAROCCI, MA ;
KIRZ, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (12) :2171-2178
[7]  
JACOBSEN C, 1988, THESIS STATE U NEW Y, P206
[8]  
JACOBSEN C, 1988, OSA P SHORT WAVELENG, V2, P303
[9]  
JOYEUX D, 1988, XRAY MICROSCOPY, V2, P246
[10]  
JOYEUX D, 1988, OSA P SHORT WAVELENG, V2, P295