An Overview of Energy Sources in Clinical Use for the Ablation of Atrial Fibrillation

被引:19
作者
Comas, George M. [1 ]
Imren, Yildirim [1 ]
Williams, Mathew R. [1 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Surg, Div Cardiothorac Surg, New York, NY USA
关键词
maze; energy sources;
D O I
10.1053/j.semtcvs.2007.01.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent years have seen many developments in the field of alternative energy sources for arrhythmia surgery. The impetus behind these advances is to replace the traditional, "cut-and-sew" Cox maze III procedure with lesion sets that are simpler, shorter, and safer but just as effective. There is demand for technology to make continuous, linear, transmural ablations reliably with a versatile energy source via an epicardial approach. This would make minimally invasive endoscopic surgical ablation of atrial fibrillation (AF) without cardiopulmonary bypass and with a closed chest feasible. These advances would shorten cardio-pulmonary bypass and improve outcomes in patients having surgical ablation and concomitant cardiac surgery. This review summarizes the technology behind alternative energy sources used to treat AF. Alternative energy sources include hypothermic sources (cryoablation) and hyperthermic sources (radiofrequency, microwave, laser, ultrasound). For each source, the biophysical background, mode of tissue injury, factors affecting lesion size, and advantages and complications are discussed. © 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 56 条
[51]   Laser energy source in surgical atrial fibrillation ablation: Preclinical experience [J].
Williams, Mathews R. ;
Casher, Jennifer M. ;
Russo, Mark J. ;
Hong, Kimberly N. ;
Argenziano, Michael ;
Oz, Mehmet C. .
ANNALS OF THORACIC SURGERY, 2006, 82 (06) :2260-2264
[52]   Application of microwave energy in cardiac tissue ablation:: From in vitro analyses to clinical use [J].
Williams, MR ;
Knaut, M ;
Bérubé, D ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 2002, 74 (05) :1500-1509
[53]   Surgical treatment of atrial fibrillation using radiofrequency energy [J].
Williams, MR ;
Stewart, JR ;
Bolling, SF ;
Freeman, S ;
Anderson, JT ;
Argenziano, M ;
Smith, CR ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 2001, 71 (06) :1939-1943
[54]  
Williams MR, 2001, CIRCULATION, V104, P409
[55]  
Wong James W W, 2004, Heart Lung Circ, V13, P302, DOI 10.1016/j.hlc.2004.03.017
[56]   EVALUATION OF MICROWAVE AND RADIO-FREQUENCY CATHETER ABLATION IN A MYOCARDIUM-EQUIVALENT PHANTOM MODEL [J].
WONNELL, TL ;
STAUFFER, PR ;
LANGBERG, JJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (10) :1086-1095