ILLUMINATION AND ERRORS IN DISPENSING

被引:97
作者
BUCHANAN, TL
BARKER, KN
GIBSON, JT
JIANG, BC
PEARSON, RE
机构
[1] AUBURN UNIV,SCH PHARM,DEPT PHARM CARE SYST,PHARM FACIL DESIGN LAB,AUBURN,AL 36849
[2] WALTER REED ARMY MED CTR,WASHINGTON,DC 20307
[3] AUBURN UNIV,SCH IND ENGN,AUBURN,AL 36849
来源
AMERICAN JOURNAL OF HOSPITAL PHARMACY | 1991年 / 48卷 / 10期
关键词
DISPENSING; ERRORS; MEDICATION; LIGHTING; PHARMACISTS; HOSPITAL; PHARMACY; INSTITUTIONAL; PLANNING AND DESIGN; PRESCRIPTIONS;
D O I
10.1093/ajhp/48.10.2137
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The relationship between the level of illumination and the prescription-dispensing error rate in a high-volume Army outpatient pharmacy was investigated. The prescription error rate was determined by direct, undisguised observation and retrospective prescription review under three levels of illumination (45, 102, and 146 foot-candles) during 21 consecutive weekdays. Illumination was controlled in the prescription-checking area of the pharmacy by using additional fluorescent lamps and filters. The three levels of illumination were randomly assigned to the 21 days to provide a total of 7 days of observations per level. The final sample consisted of 10,888 prescriptions dispensed by five pharmacists. The overall prescription error rate (including both content and labeling errors) was 3.39% (369 prescriptions). An illumination level of 146 foot-candles was associated with a significantly lower error rate (2.6%) than the baseline level of 45 foot-candles (3.8%). There was a linear relationship between each pharmacist's error rate and that pharmacist's corresponding daily prescription workload for all three illumination levels. The effect of the observer was minimal. The rate of prescription-dispensing errors was associated with the level of illumination. Ergonomics can affect the performance of professional tasks.
引用
收藏
页码:2137 / 2145
页数:9
相关论文
共 51 条
[41]  
SAFREN MA, 1960, HOSPITALS, V34, P66
[42]  
Safren MA, 1960, HOSPITALS, V34, P64
[43]  
Safren MA, 1960, HOSPITALS, V34, P68
[44]  
SCHNELL BR, 1976, CAN J HOSP PHARM, V39, P85
[45]   PERFORMANCE OF A READING TEST UNDER DIFFERENT LEVELS OF ILLUMINATION [J].
SMITH, SW ;
REA, MS .
JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1982, 12 (01) :29-33
[46]   CHECK VALUE VERIFICATION UNDER DIFFERENT LEVELS OF ILLUMINATION [J].
SMITH, SW ;
REA, MS .
JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1987, 16 (01) :143-149
[47]  
SMITH SW, 1978, J IESNA OCT, P47
[48]  
SMITH SW, 1978, J ILLUM ENG SOC JUL, P255
[49]   INSPECTION OF SHEET MATERIALS - TEST OF MODEL PREDICTIONS [J].
SPITZ, G ;
DRURY, CG .
HUMAN FACTORS, 1978, 20 (05) :521-528
[50]  
WESTON HC, 1945, 87 IND HLTH RES BOAR