AN ALL-SOLID-STATE FLOW CYTOMETER FOR COUNTING FLUORESCENT MICROSPHERES

被引:23
作者
NIEHREN, S [1 ]
KINZELBACH, W [1 ]
SEEGER, S [1 ]
WOLFRUM, J [1 ]
机构
[1] UNIV HEIDELBERG,INST CHEM PHYS,D-69120 HEIDELBERG,GERMANY
关键词
D O I
10.1021/ac00111a027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Particle tracers are of interest in the investigation of fractured media, Because their transport behavior differs from that of solute tracers, they supply complementary information on fracture space, This information is crucial in the risk assessment of underground hazardous waste storage sites, An easy-to-handle particle tracer consists of fluorescent polystyrene spheres with diameters on the order of 1 mu m. Up to now, detection and counting of these particles was performed by fluorescence microscopy of filtered samples, To allow faster and on-line continuous monitoring of single particles, a flow cytometer has been developed in the present work, The cytometer is built from solid-state optical components, resulting in a robust and transportable system suitable for field use, To maximize the fluorescence quantum efficiency, a new dye, JA22, was used, Use of an avalanche diode allowed the efficiency of photon detection to be maximized, For complete digital data acquisition and analysis, only a personal computer is required, The detection efficiency of the cytometer is > 25%, the probe now is 20 mL/h, and the present accuracy is < 160 particles/mL.
引用
收藏
页码:2666 / 2671
页数:6
相关论文
共 22 条
[1]  
[Anonymous], 1986, QUANTITATIVE HYDROGE
[2]  
ARDENJACOB J, 1992, NEUE LANGWELLIGE XAN
[3]  
Bitton G., 1992, Environmental microbiology., P103
[4]  
Buddemeier R. W., 1988, APPL GEOCHEM, V3, P535, DOI DOI 10.1016/0883-2927(88)90025-X
[5]   VISIBLE DIODE-LASERS CAN BE USED FOR FLOW CYTOMETRIC IMMUNOFLUORESCENCE AND DNA ANALYSIS [J].
DOORNBOS, RMP ;
DEGROOTH, BG ;
KRAAN, YM ;
VANDERPOEL, CJ ;
GREVE, J .
CYTOMETRY, 1994, 15 (03) :267-271
[6]   WHITE BLOOD-CELL DIFFERENTIATION USING A SOLID-STATE FLOW CYTOMETER [J].
DOORNBOS, RMP ;
HENNINK, EJ ;
PUTMAN, CAJ ;
DEGROOTH, BG ;
GREVE, J .
CYTOMETRY, 1993, 14 (06) :589-594
[7]  
DRACOS T, 1994, TRANSPORT REACTIVE P
[8]  
Eberly J., 1988, LASERS
[9]   ROLE OF PHYSICAL HETEROGENEITY IN THE INTERPRETATION OF SMALL-SCALE LABORATORY AND FIELD OBSERVATIONS OF BACTERIA, MICROBIAL-SIZED MICROSPHERE, AND BROMIDE TRANSPORT THROUGH AQUIFER SEDIMENTS [J].
HARVEY, RW ;
KINNER, NE ;
MACDONALD, D ;
METGE, DW ;
BUNN, A .
WATER RESOURCES RESEARCH, 1993, 29 (08) :2713-2721
[10]   WATER-SOLUBLE POLYSTYRENE LATEXES AS PHOTOREDOX MEDIA .1. INTERFACIAL FLUORESCENCE QUENCHING AND TRIPLET-STATE ELECTRON-TRANSFER FROM PYRENE AND 1-PYRENEBUTYRIC ACID [J].
HSIAO, JS ;
WEBBER, SE .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (31) :8289-8295