MODELING INDUSTRIAL WASTE-WATER OZONATION IN BUBBLE CONTACTORS .1. RATE COEFFICIENT DETERMINATION

被引:31
作者
BELTRAN, FJ
ENCINAR, JM
GARCIAARAYA, JF
MUNOZ, MG
机构
[1] Departamento de Ingeniería Química y Energética, Universidad de Extremadura
关键词
OZONE; INDUSTRIAL WASTE-WATER TREATMENT; WASTE-WATER OZONATION; OZONATION KINETICS; MODELING OZONATION IN BUBBLE CONTACTORS; OZONE RATE COEFFICIENT DETERMINATIONS; OZONATION OF TOMATO WASTEWATERS; OZONATION OF DISTILLERY WASTEWATERS;
D O I
10.1080/01919519508547344
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A study of the ozonation of distillery and tomato wastewaters was carried out in a small bubble contactor in order to obtain kinetic data for scaling-up. Thus, several parameters, such as chemical oxygen demand (COD), 254 nm absorbance (A(254)) and organic carbon content (OC), were followed during ozonation at different experimental conditions. For distillery wastewaters all parameters investigated have the highest decreases during the first minutes of ozonation, A(254) showing the highest disappearance rates. Thus, during the first fifteen minutes of ozonation an important decrease of the 254 nm absorbance (similar to 75%) was observed. At further reaction times values of all parameters studied decrease slowly, eventually reaching a plateau value. During approximately the first two hours of reaction, dissolved ozone was never found, which suggested that fast or moderate gas-liquid reactions took place in the wastewaters. Regarding tomato wastewaters, COD, OC and A(254) reach reductions of up to 70%, 40% and 90%, respectively, in one hour of ozonation. In this case the presence of dissolved ozone suggested that the kinetic regime of ozone absorption corresponded to a slow reaction. Application of an ozone balance in gas and water phases, along with the kinetic equation for ozone absorption with chemical reaction lead to determination of physico-chemical parameters like Henry's law constant and reaction rate coefficient, Eo, In spite of the limitations concerning actual values of mass transfer coefficient, specific interfacial areas and ozone diffusivity, the rate coefficient obtained was found to be independent of hydrodynamic conditions, although it diminished with reaction time. This, however, was in agreement with the changing nature of the wastewater content.
引用
收藏
页码:355 / 378
页数:24
相关论文
共 33 条
[21]   MASS-TRANSFER AND SELECTIVITY OF OZONE REACTIONS [J].
MEHTA, YM ;
GEORGE, CE ;
KUO, CH .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1989, 67 (01) :118-126
[22]   MULTISTAGE OZONE TREATMENT OF DYE WASTE [J].
RAKOCZI, F .
OZONE-SCIENCE & ENGINEERING, 1991, 13 (01) :11-21
[23]  
Reid R.C., 1977, PROPERTIES GASES LIQ
[24]  
RICE RG, 1980, EPA600280060 REP
[25]  
SANTOS JF, 1982, WISSENSCHAFT UMWELT, V4, P250
[26]  
SANTOSOLIVEIRA JF, 1980, ENVIRON TECHNOL LETT, V1, P125
[27]   OZONATION OF AQUEOUS-SOLUTIONS OF RESORCINOL AND PHLOROGLUCINOL .1. STOICHIOMETRY AND ABSORPTION KINETIC REGIME [J].
SOTELO, JL ;
BELTRAN, FJ ;
GONZALEZ, M .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1990, 29 (12) :2358-2367
[28]   EFFICIENCY OF OZONATION AS A UNIT PROCESS IN THE TREATMENT OF SECONDARY EFFLUENTS FROM THE PULP AND PAPER-INDUSTRY [J].
SOZANSKA, Z ;
SOZANSKI, MM .
OZONE-SCIENCE & ENGINEERING, 1991, 13 (05) :521-534
[29]  
TOWELL GD, 1965, P AICHE I CHEM ENG, V10, P97
[30]  
VALLINI G, 1984, BIOCYCLE MAY, P43