FAILURE OF GLOW-DISCHARGE POLYMERIZATION ONTO WOVEN DACRON TO IMPROVE PERFORMANCE OF HEMODIALYSIS GRAFTS

被引:2
作者
FARMER, DL [1 ]
GOLDSTONE, J [1 ]
LIM, RC [1 ]
REILLY, LM [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT SURG,DIV VASC SURG,M-488,505 PARNASSUS AVE,SAN FRANCISCO,CA 94143
关键词
D O I
10.1016/0741-5214(93)90066-U
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The ideal conduit for hemodialysis vascular access remains elusive. Autogenous fistulas and prosthetic grafts, most commonly expanded polytetrafluoroethylene (e-PTFE), have adequate long-term patency rates (60% to 80% at 1 year); however, considerable delay in their use (2 to 6 weeks) is required. The Plasma-TFE graft is a recently introduced thin-walled woven Dacron graft to which an ultrathin layer of tetrafluoroethylene is bonded through a process of glow-discharge polymerization. This process purportedly results in a graft with an internal surface of low thrombogenicity. Low thrombogenicity, combined with the healing characteristics of a woven graft, have led to claims of equivalent patency rates even when used for dialysis immediately (within 1 week) after implantation. Methods: This concept led us to use this new graft material in 19 fistulas (12 forearm and 7 arm) during a 1-year period. Results. Although early use was possible, the primary and secondary patency rate at 12 months was only 47.4%. Ten grafts required replacement, five within the first month and two in the second month. Attempts at fistula revision failed because of unsuccessful graft thrombectomy or exuberant intimal hyperplasia. Failure was not associated with early use. During the same time period, 28 PTFE grafts were implanted, with only four failures (primary patency 78.6%; secondary patency 85.7%; p = 0.028). The secondary patency rate was the same for Plasma-TFE grafts (47%) but improved to 85.7% for e-PTFE grafts (p = 0.005). Both groups were comparable with respect to age, diabetes, previous dialysis access procedures, and other comorbid conditions. Conclusions: These early results have been sufficiently disappointing that we have abandoned use of this graft approved for hemodialysis by the Food and Drug Administration and cannot recommend it for other clinical indications. Nevertheless, the concept of plasma-discharge polymerization is theoretically attractive and might be useful in future graft configurations.
引用
收藏
页码:570 / 576
页数:7
相关论文
共 15 条
[1]   SUBCLAVIAN STENOSIS - A MAJOR COMPLICATION OF SUBCLAVIAN DIALYSIS CATHETERS [J].
BARRETT, N ;
SPENCER, S ;
MCIVOR, J ;
BROWN, EA .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1988, 3 (04) :423-425
[2]   CHRONIC HEMODIALYSIS USING VENIPUNCTURE AND A SURGICALLY CREATED ARTERIOVENOUS FISTULA [J].
BRESCIA, MJ ;
CIMINO, JE ;
APPEL, K ;
HURWICH, BJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1966, 275 (20) :1089-&
[3]  
CANIZALES S, 1989, CAN J SURG, V32, P433
[4]   GRAFT GEOMETRY AND VENOUS INTIMAL-MEDIAL HYPERPLASIA IN ARTERIOVENOUS LOOP GRAFTS [J].
FILLINGER, MF ;
REINITZ, ER ;
SCHWARTZ, RA ;
RESETARITS, DE ;
PASKANIK, AM ;
BRUCH, D ;
BREDENBERG, CE .
JOURNAL OF VASCULAR SURGERY, 1990, 11 (04) :556-566
[5]   A PROSPECTIVE EVALUATION OF PLASMA-TFE AND EXPANDED PTFE GRAFTS FOR ROUTINE AND EARLY USE AS VASCULAR ACCESS DURING HEMODIALYSIS [J].
HELLING, TS ;
NELSON, PW ;
SHELTON, L .
ANNALS OF SURGERY, 1992, 216 (05) :596-599
[6]   COMPARISON OF AUTOGENOUS FISTULA VERSUS EXPANDED POLYTETRAFLUOROETHYLENE GRAFT FISTULA FOR ANGIOACCESS IN HEMODIALYSIS [J].
KHERLAKIAN, GM ;
ROEDERSHEIMER, LR ;
ARBAUGH, JJ ;
NEWMARK, KJ ;
KING, LR .
AMERICAN JOURNAL OF SURGERY, 1986, 152 (02) :238-243
[7]  
KIAEI D, 1992, J BIOMAT SCI-POLYM E, V4, P35
[8]   VASCULAR ACCESS FOR HEMODIALYSIS - PATENCY RATES AND RESULTS OF REVISION [J].
PALDER, SB ;
KIRKMAN, RL ;
WHITTEMORE, AD ;
HAKIM, RM ;
LAZARUS, JM ;
TILNEY, NL .
ANNALS OF SURGERY, 1985, 202 (02) :235-239
[9]  
RAJU S, 1987, ANN SURG, V206, P666
[10]   LONG-TERM PATENCY OF POLYTETRAFLUOROETHYLENE GRAFT FISTULAS [J].
SCHUMAN, ES ;
GROSS, GF ;
HAYES, JF ;
STANDAGE, BA .
AMERICAN JOURNAL OF SURGERY, 1988, 155 (05) :644-646