UV-TRANSPARENT, REPLACEABLE AGAROSE GELS FOR MOLECULAR-SIEVE (CAPILLARY) ELECTROPHORESIS OF PROTEINS AND NUCLEIC-ACIDS

被引:25
作者
HJERTEN, S
SRICHAIYO, T
PALM, A
机构
[1] Department of Biochemistry, Uppsala University, Biomedical Center, Uppsala, S-751 23
关键词
D O I
10.1002/bmc.1130080206
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gels of methoxylated agarose (gelling point 25.6 degrees C) and other low-melting agarose derivatives compare favorably with cross-linked polyacrylamide gels for capillary and slab molecular-sieve electrophoresis of proteins and DNA. These agarose gels can be pressed out of the capillary following a run and replaced by an agarose solution with a temperature of 35-40 degrees C. Gelation occurs upon lowering the temperature and the same capillary can thus be reused for another analysis with a fresh gel. The methoxylated, non UV-absorbing agarose gels are, accordingly, replaceable, which makes them very attractive for series analyses with modern, automated capillary electrophoresis apparatus. The high resolution of these agarose gels is demonstrated with a separation of an albumin sample into monomers, dimers, trimers, tetramers, pentamers, hexamers, heptamers, and of DNA fragments.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 11 条
[2]  
BODE HJ, 1976, FEBS LETT, V65, P56, DOI 10.1016/0014-5793(76)80620-5
[3]   USE OF LIQUID POLYACRYLAMIDE IN ELECTROPHORESIS .1. MIXED GELS COMPOSED OF AGAR-AGAR AND LIQUID POLYACRYLAMIDE [J].
BODE, HJ .
ANALYTICAL BIOCHEMISTRY, 1977, 83 (01) :204-210
[4]   UN-SUPERCOILED AGAROSE WITH A DEGREE OF MOLECULAR-SIEVING SIMILAR TO THAT OF CROSSLINKED POLYACRYLAMIDE [J].
BUZAS, Z ;
CHRAMBACH, A .
ELECTROPHORESIS, 1982, 3 (03) :130-134
[5]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS OF SDS PROTEIN COMPLEXES USING UV-TRANSPARENT POLYMER NETWORKS [J].
GANZLER, K ;
GREVE, KS ;
COHEN, AS ;
KARGER, BL ;
GUTTMAN, A ;
COOKE, NC .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2665-2671
[6]   HIGH-PERFORMANCE ELECTROPHORESIS - THE ELECTROPHORETIC COUNTERPART OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :1-6
[7]  
HJERTEN S, 1985, J CHROMATOGR, V347, P181
[8]   ELECTROPHORESIS ON UNCROSSLINKED POLYACRYLAMIDE - MOLECULAR-SIEVING AND ITS POTENTIAL APPLICATIONS [J].
TIETZ, D ;
GOTTLIEB, MH ;
FAWCETT, JS ;
CHRAMBACH, A .
ELECTROPHORESIS, 1986, 7 (05) :217-220
[9]   CAPILLARY ZONE ELECTROPHORESIS WITH A LINEAR, NON-CROSS-LINKED POLYACRYLAMIDE-GEL - SEPARATION OF PROTEINS ACCORDING TO MOLECULAR MASS [J].
WIDHALM, A ;
SCHWER, C ;
BLAAS, D ;
KENNDLER, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :446-451
[10]   FACTORS AFFECTING FREE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN CAPILLARY ELECTROPHORESIS [J].
ZHU, MD ;
HANSEN, DL ;
BURD, S ;
GANNON, F .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :311-319