APPLICATION OF GAS-CHROMATOGRAPHIC RETENTION PROPERTIES TO THE IDENTIFICATION OF ENVIRONMENTAL CONTAMINANTS

被引:18
作者
DONNELLY, JR [1 ]
ABDELHAMID, MS [1 ]
JETER, JL [1 ]
GURKA, DF [1 ]
机构
[1] US EPA,ENVIRONM MONITORING SYST LAB,LAS VEGAS,NV 89193
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 642卷 / 1-2期
关键词
D O I
10.1016/0021-9673(93)80106-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gas chromatographic retention indices (I) were measured for congeners of commonly encountered classes of environmental contaminants, which are often reported as tentatively identified compounds. Several commonly encountered polycyclic aromatic hydrocarbons were employed as I reference standards. These indices were related to boiling points with reasonable accuracy, allowing the estimation of I for additional members of those classes.