MONTE-CARLO AIDED DOSIMETRY OF THE MICROSELECTRON PULSED AND HIGH-DOSE-RATE IR-192 SOURCES

被引:196
作者
WILLIAMSON, JF
LI, ZF
机构
[1] Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri
关键词
HIGH DOSE-RATE BRACHYTHERAPY; PULSED DOSE-RATE BRACHYTHERAPY DOSIMETRY; IR-192; MONTE CARLO SIMULATION;
D O I
10.1118/1.597483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite the large number of single-stepping source pulsed and high dose-rate (HDR) remote after-loading devices in clinical use, the published literature contain little data characterizing dose-rate distributions around the high-intensity (4×103-4×104μGy m2h−1) 192Ir sources currently used in these devices. We have used the Monte Carlo method to calculate complete two-dimensional dose-rate distributions about the most widely used high dose-rate source design, as well as the Nucletron pulsed dose-rate (PDR) Ir source. A Monte Carlo photon transport code, incorporating the detailed internal geometry of the source, was used to calculate the dose rate per unit air-kerma strength in water medium on the transverse bisecting axis over the 0.15-12 cm distance range. In addition, polar dose profiles were calculated at distances ranging from 0.25 to 5 cm. The PDR and HDR dose-rate distributions are tabulated using the formalism endorsed by the Interstitial Collaborative Working Group and the AAPM Task Group 43, and includes dose-rate constant, radial dose function, anisotropy function, geometry function, and anisotropy factors. The dose-rate constants, A, of the MicroSelectron/HDR and PDR sources were found to be 1.115 and 1.128 cGyh−1per unit air-kerma strength, respectively, in good agreement with previously published data for low dose-rate interstitial Ir sources. Oblique filtration by the high-density iridium metal core resulted in deviations from anisotropy as large as 35%-55% near the longitudinal axis of the source. Dose-rate distributions are also presented in Cartesian (“away” and “along”) coordinates. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:809 / 819
页数:11
相关论文
共 31 条
[1]   AUTORADIOGRAPHY FOR I-125 SEEDS [J].
ALBERTI, W ;
DIVOUX, S ;
POTHMANN, B ;
TABOR, P ;
HERMANN, KP ;
HARDER, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (05) :881-884
[2]  
ANDERSON LL, 1990, INTERSTITIAL COLLABO
[3]  
BALTUS D, 1992, INT BRACHYTHERAPY, P290
[4]   FRACTIONATED HIGH-DOSE RATE VERSUS LOW-DOSE RATE REGIMENS FOR INTRACAVITARY BRACHYTHERAPY OF THE CERVIX .1. GENERAL-CONSIDERATIONS BASED ON RADIOBIOLOGY [J].
BRENNER, DJ ;
HALL, EJ .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (758) :133-141
[5]  
CERRA F, 1990, ENDOCUR HYPERTHER ON, V6, P71
[6]  
CHIUTSAO ST, 1987, MED PHYS, V14, P478
[7]  
EZZELL GA, 1994, IN PRESS MODERN CLIN
[8]  
GLASGOW G P, 1979, Medical Physics (Woodbury), V6, P49, DOI 10.1118/1.594551
[9]  
Jenkins TM., 1988, MONTE CARLO TRANSPOR
[10]  
KIROV AS, 1995, MED PHYS, V21, P881