Sensitivity of photoacoustic microscopy

被引:367
作者
Yao, Junjie [1 ]
Wang, Lihong V. [1 ]
机构
[1] Washington Univ, Dept Biomed Engn, Opt Imaging Lab, St Louis, MO 63130 USA
关键词
Photoacoustic microscopy; Detection sensitivity; Absorption contrast; Ultrasonic transducer; Early cancer detection; Contrast agents;
D O I
10.1016/j.pacs.2014.04.002
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given percentage change in the optical absorption coefficient yields the same percentage change in the photoacoustic amplitude), and its ultimate detection sensitivity is limited only by thermal noise. Focusing on the engineering aspects of PAM, this Review discusses the detection sensitivity of PAM, compares the detection efficiency of different PAM designs, and summarizes the imaging performance of various endogenous and exogenous contrast agents. It then describes representative PAM applications with high detection sensitivity, and outlines paths to further improvement. (C) 2014 The Authors. Published by Elsevier GmbH.
引用
收藏
页码:87 / 101
页数:15
相关论文
共 144 条
[1]
Biomedical photoacoustic imaging [J].
Beard, Paul .
INTERFACE FOCUS, 2011, 1 (04) :602-631
[2]
A 3-D High-Frequency Array Based 16 Channel Photoacoustic Microscopy System for In Vivo Micro- Vascular Imaging [J].
Bitton, Rachel ;
Zemp, Roger ;
Yen, Jesse ;
Wang, Lihong V. ;
Shung, K. Kirk .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (08) :1190-1197
[3]
High Frequency Optoacoustic Microscopy [J].
Bost, Wolfgang ;
Stracke, Frank ;
Weiss, Eike C. ;
Narasimhan, Sankar ;
Kolios, Michael C. ;
Lemor, Robert .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :5883-+
[4]
Pulsed photoacoustic Doppler flowmetry using a cross-correlation method [J].
Brunker, J. ;
Beard, P. .
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
[5]
Photoacoustic point source [J].
Calasso, IG ;
Craig, W ;
Diebold, GJ .
PHYSICAL REVIEW LETTERS, 2001, 86 (16) :3550-3553
[6]
Functional photoacoustic microscopy of pH [J].
Chatni, Muhammad Rameez ;
Yao, Junjie ;
Danielli, Amos ;
Favazza, Christopher P. ;
Maslov, Konstantin I. ;
Wang, Lihong V. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (10)
[7]
A fiber-optic system for dual-modality photoacoustic microscopy and confocal fluorescence microscopy using miniature components [J].
Chen, Sung-Liang ;
Xie, Zhixing ;
Guo, L. Jay ;
Wang, Xueding .
PHOTOACOUSTICS, 2013, 1 (02) :30-35
[8]
Photoacoustic correlation spectroscopy and its application to low-speed flow measurement [J].
Chen, Sung-Liang ;
Ling, Tao ;
Huang, Sheng-Wen ;
Baac, Hyoung Won ;
Guo, L. Jay .
OPTICS LETTERS, 2010, 35 (08) :1200-1202
[9]
Polymer Microring Resonators for High-Sensitivity and Wideband Photoacoustic Imaging [J].
Chen, Sung-Liang ;
Huang, Sheng-Wen ;
Ling, Tao ;
Ashkenazi, Shai ;
Guo, L. Jay .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (11) :2482-2491
[10]
Cobbold RSC, 2007, FDN BIOMEDICAL ULTRA, Vxix, P802