RETENTION AND ENANTIOSELECTIVITY OF 2-ARYLPROPIONIC ACID-DERIVATIVES ON AN AVIDIN-BONDED SILICA COLUMN INFLUENCE OF BASE MATERIALS, SPACER TYPE AND PROTEIN MODIFICATION

被引:25
作者
HAGINAKA, J
MURASHIMA, T
SEYAMA, C
机构
[1] Faculty of Pharmaceutical Sciences, Mukogawa Women's University, Nishinomiya, 663, 11-68, Koshien Kyuban-cho
关键词
D O I
10.1016/0021-9673(94)80151-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The influences of pore sizes of base materials, spacer type and protein modification on the chiral resolution of 2-arylpropionic acid derivatives on avidin (AVD)-bonded silica materials were investigated. With regard to the pore sizes of the base silica materials, 120-Angstrom A materials gave higher enantioselectivity and resolution than 300-Angstrom A materials. With regard to spacer type, aminopropyl (AP)-silica gels activated by N,N'-disuccinimidyl carbonate (DSC) and N,N'-disuccinimidyl suberate (DSS) and glycerylpropyl (GP)-silica gels activated by 1,1'-carbonyldiimidazole (CDI) were compared. The AP-silica gels activated by DSC gave the highest protein coverage and resolution. Modified AVD-bonded materials were prepared by reaction with glutaraldehyde, glyceraldehyde and benzaldehyde. The retentive and enantioselective properties of 2-arylpropionic acid derivatives on these modified AVD columns were compared with those on an unmodified AVD column. The retentions of 2-arylpropionic acid derivatives on the modified AVD columns were shorter than those on the unmodified AVD column, whereas the modified AVD columns gave lower or approximately equal enantioselectivity compared with the unmodified AVD column. These results may be attributed to a decrease in the number of ion-exchange sites for retention and chiral recognition, and/or changes in protein conformation as a result of modification.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 12 条
[1]   DIRECT LIQUID-CHROMATOGRAPHIC SEPARATION OF ENANTIOMERS ON IMMOBILIZED PROTEIN STATIONARY PHASES .9. INFLUENCE OF THE CROSS-LINKING REAGENT ON THE RETENTIVE AND ENANTIOSELECTIVE PROPERTIES OF CHIRAL SORBENTS BASED ON BOVINE SERUM-ALBUMIN [J].
ANDERSSON, S ;
THOMPSON, RA ;
ALLENMARK, SG .
JOURNAL OF CHROMATOGRAPHY, 1992, 591 (1-2) :65-73
[2]   DIRECT LIQUID-CHROMATOGRAPHIC SEPARATION OF ENANTIOMERS ON IMMOBILIZED PROTEIN STATIONARY PHASES .8. A COMPARISON OF A SERIES OF SORBENTS BASED ON BOVINE SERUM-ALBUMIN AND ITS FRAGMENTS [J].
ANDERSSON, S ;
ALLENMARK, S ;
ERLANDSSON, P ;
NILSSON, S .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :81-91
[3]   IMMOBILIZED CELLULASE (CBH I) AS A CHIRAL STATIONARY PHASE FOR DIRECT RESOLUTION OF ENANTIOMERS [J].
ERLANDSSON, P ;
MARLE, I ;
HANSSON, L ;
ISAKSSON, R ;
PETTERSSON, C ;
PETTERSSON, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (11) :4573-4574
[4]   RETENTION AND ENANTIOSELECTIVITY OF RACEMIC SOLUTES ON A MODIFIED OVOMUCOID-BONDED COLUMN .1. CROSS-LINKING WITH GLUTARALDEHYDE [J].
HAGINAKA, J ;
SEYAMA, C ;
YASUDA, H ;
FUJIMA, H ;
WADA, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2) :301-307
[5]  
HAGINAKA J, 1992, J CHROMATOGR, V631, P183
[6]   DIRECT LIQUID-CHROMATOGRAPHIC RESOLUTION OF RACEMIC DRUGS USING ALPHA-1-ACID GLYCOPROTEIN AS THE CHIRAL STATIONARY PHASE [J].
HERMANSSON, J .
JOURNAL OF CHROMATOGRAPHY, 1983, 269 (02) :71-80
[7]   THE EFFECTS OF PH AND ALCOHOLIC ORGANIC MODIFIERS ON THE DIRECT SEPARATION OF SOME ACIDIC, BASIC AND NEUTRAL COMPOUNDS ON A COMMERCIALLY AVAILABLE OVOMUCOID COLUMN [J].
IREDALE, J ;
AUBRY, AF ;
WAINER, I .
CHROMATOGRAPHIA, 1991, 31 (7-8) :329-334
[8]  
MIWA T, 1987, CHEM PHARM BULL, V35, P682
[9]   CHARACTERISTICS OF AN AVIDIN-CONJUGATED COLUMN IN DIRECT LIQUID-CHROMATOGRAPHIC RESOLUTION OF RACEMIC COMPOUNDS [J].
MIWA, T ;
MIYAKAWA, T ;
MIYAKE, Y .
JOURNAL OF CHROMATOGRAPHY, 1988, 457 :227-233
[10]   AVIDIN PROTEIN-CONJUGATED COLUMN FOR DIRECT INJECTION-ANALYSIS OF DRUG ENANTIOMERS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ODA, Y ;
ASAKAWA, N ;
ABE, S ;
YOSHIDA, Y ;
SATO, T .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 572 (1-2) :133-141