DETERMINATION OF AFLATOXIN Q(1) IN URINE BY AUTOMATED IMMUNOAFFINITY COLUMN CLEANUP AND LIQUID-CHROMATOGRAPHY

被引:13
作者
KUSSAK, A [1 ]
ANDERSSON, B [1 ]
ANDERSSON, K [1 ]
机构
[1] NATL INST OCCUPAT HLTH,DIV ANALYT CHEM,S-90713 UMEA,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 656卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00123-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatographic system with an automated clean-up procedure for aflatoxin Q(1) in human urine is described. The samples were cleaned up by using immunoaffinity columns originally designed for aflatoxin M(1). The chromatographic system was a C-18 column with an acidic mobile phase of acetonitrile-water containing potassium bromide. Fluorescence detection (365/440 nm) of aflatoxin Q(1) was enhanced by addition of bromine, using post-column derivatization, which was studied by factorial designs. Average recovery of aflatoxin Q(1) in spiked 10-ml urine samples was 88% (R.S.D. = 6.4%) at a level of 50 pg/ml. The determination limit was 49.5 pg/ml urine.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 18 条
  • [1] DETERMINATION OF EXPOSURE TO AFLATOXINS AMONG DANISH WORKERS IN ANIMAL-FEED PRODUCTION THROUGH THE ANALYSIS OF AFLATOXIN-B1 ADDUCTS TO SERUM-ALBUMIN
    AUTRUP, JL
    SCHMIDT, J
    SEREMET, T
    AUTRUP, H
    [J]. SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1991, 17 (06) : 436 - 440
  • [2] BETINA V, 1989, BIOACTIVE MOL, V9
  • [3] CARLSON R, 1992, DESIGN OPTIMIZATION
  • [4] TANDEM CHROMATOGRAPHIC-IMMUNOLOGICAL ANALYSES
    DEFRUTOS, M
    REGNIER, FE
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (01) : A17 - &
  • [5] EATON DL, 1990, 1988 P S MICR TOX FO
  • [6] DETERMINATION OF AFLATOXIN-M1 USING A DIALYSIS-BASED IMMUNOAFFINITY SAMPLE PRETREATMENT SYSTEM COUPLED ONLINE TO LIQUID-CHROMATOGRAPHY - REUSABLE IMMUNOAFFINITY COLUMNS
    FARJAM, A
    VANDEMERBEL, NC
    NIEMAN, AA
    LINGEMAN, H
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2): : 141 - 149
  • [7] GROOPMAN JD, 1992, CANCER EPIDEM BIOMAR, V1, P221
  • [8] DETERMINATION OF AFLATOXINS IN CATTLE FEED BY LIQUID-CHROMATOGRAPHY AND POSTCOLUMN DERIVATIZATION WITH ELECTROCHEMICALLY GENERATED BROMINE
    KOK, WT
    VANNEER, TCH
    TRAAG, WA
    TUINSTRA, LGMT
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 367 (01): : 231 - 236
  • [9] AUTOMATED SAMPLE CLEANUP WITH SOLID-PHASE EXTRACTION FOR THE DETERMINATION OF AFLATOXINS IN URINE BY LIQUID-CHROMATOGRAPHY
    KUSSAK, A
    ANDERSSON, B
    ANDERSSON, K
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (02): : 235 - 241
  • [10] METABOLISM OF AFLATOXIN-B1 IN THE BOVINE OLFACTORY MUCOSA
    LARSSON, P
    PETTERSSON, H
    TJALVE, H
    [J]. CARCINOGENESIS, 1989, 10 (06) : 1113 - 1118