DOSIMETRIC CONTROL OF CONFORMAL TREATMENT OF PAROTID-GLAND TUMORS

被引:18
作者
ESSERS, M
KEUS, R
LANSON, JH
MIJNHEER, BJ
机构
[1] The Netherlands Cancer Institute, 1066 CX Amsterdam, Antoni Leeuwenhoek Huis
关键词
PAROTID TUMORS; QUALITY ASSURANCE; IN VIVO DOSIMETRY; 3D TREATMENT PLANNING; RADIOTHERAPY;
D O I
10.1016/0167-8140(94)90102-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to determine the dosimetric accuracy of the treatment of parotid gland tumours using 8 MV X-ray beams. These tumours are generally situated near the patient's skin. Entrance in vivo dose measurements with diodes were obtained for 20 patients during 5 sessions per patient, in the anterior-oblique and posterior-oblique wedged fields, on the central beam axis as well as in points situated in a cranial plane 2 or 3 cm off-axis. Phantom measurements were performed in order to determine the actual position of the 95% isodose surface. The measurements were compared with calculations performed with our three-dimensional treatment planning system. The reproducibility of the diode measurement of patients was found to be 1.4% (1 SD). The total accuracy in the entrance dose determination for the average of 2 measurements was 1.8% (1 SD). The central axis entrance dose for the anterior field was on average 1.5% +/- 3.2% (1 SD) higher than the calculated value. For the posterior field, the difference was 0.9% +/- 3.1% (1 SD). The deviations for the off-axis points were somewhat smaller, mainly due to overestimation of the block effect in the calculations. The value of the dose at the isocentre, obtained by extrapolation of the measured entrance dose values, differed 0.3% +/- 2.1% from the calculations. The accuracy in dose determination at the isocentre was 2% (1 SD). After correction for the difference in prescribed and actual source-to-skin distance, the results showed good agreement with phantom measurements on a polystyrene phantom without inhomogeneities, performed both with diodes and an ionization chamber. The measured 95% isodose surface was situated 10.6 mm under the phantom surface, which meant a shift of 0.5 mm towards the surface compared with calculations. A 1-15 mm shift towards the block edges was observed. These results formed the basis of a disometric quality assurance protocol. The entrance dose on the central beam axis is measured twice at the beginning of the treatment. The total dose at the isocentre is calculated using the percentage depth dose values. If the difference between the average measured and calculated dose at the isocentre is larger than 4% (2 SD of the measurement accuracy at the isocentre), the reason for the discrepancy will be investigated and, if necessary, the number of monitor units will be adjusted.
引用
收藏
页码:154 / 162
页数:9
相关论文
共 19 条
[1]  
BRAHME A, 1988, ACTA ONCOL S, V1
[2]   IN-VIVO DOSIMETRY DURING CONFORMAL THERAPY OF PROSTATIC-CANCER [J].
ESSERS, M ;
LANSON, JH ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :271-279
[3]  
Fraass B. A., 1987, USE COMPUTERS RAD TH, P521
[4]  
Fraass B. A., 1987, USE COMPUTERS RAD TH, P273
[5]   CALCULATION OF THE UNCERTAINTY IN THE DOSE DELIVERED DURING RADIATION-THERAPY [J].
GOITEIN, M .
MEDICAL PHYSICS, 1985, 12 (05) :608-612
[6]   WEDGE FACTOR CONSTITUENTS OF HIGH-ENERGY PHOTON BEAMS - FIELD SIZE AND DEPTH DEPENDENCE [J].
HEUKELOM, S ;
LANSON, JH ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1994, 30 (01) :66-73
[7]   COMPARISON OF ENTRANCE AND EXIT DOSE MEASUREMENTS USING IONIZATION CHAMBERS AND SILICON DIODES [J].
HEUKELOM, S ;
LANSON, JH ;
MIJNHEER, BJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :47-59
[8]   INVIVO DOSIMETRY DURING TANGENTIAL BREAST TREATMENT [J].
HEUKELOM, S ;
LANSON, JH ;
VANTIENHOVEN, G ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :269-279
[9]   INVIVO DOSIMETRY DURING PELVIC TREATMENT [J].
HEUKELOM, S ;
LANSON, JH ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1992, 25 (02) :111-120
[10]   THE EFFECT OF CUSTOMIZED BEAM SHAPING ON NORMAL TISSUE COMPLICATIONS IN RADIATION-THERAPY OF PAROTID-GLAND TUMORS [J].
KEUS, R ;
NOACH, P ;
DEBOER, R ;
LEBESQUE, J .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (03) :211-217