APPLICATION OF CAPILLARY ISOTACHOPHORESIS IN PEPTIDE ANALYSIS

被引:37
作者
KASICKA, V [1 ]
PRUSIK, Z [1 ]
机构
[1] CZECHOSLOVAK ACAD SCI, INST ORGAN CHEM & BIOCHEM, FLEMINGOVA 2, CS-16610 PRAGUE 6, CZECHOSLOVAKIA
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 569卷 / 1-2期
关键词
D O I
10.1016/0378-4347(91)80228-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper gives a broad and detailed review of the applications of one of the modern high-performance electromigration separation techniques - capillary isotachophoresis (ITP) - in peptide analysis. Examples are presented of the utilization of capillary ITP for peptide analysis in the fields of chemistry, general and clinical biochemistry, biology, biotechnology, pharmacy and the food industry. The complete composition of all the electrolyte systems used for peptide ITP analyses in both cationic and anionic techniques is given in tabular form. According to the purpose of analysis the applications are divided into several sections: model studies, determination of physico-chemical characteristics, purity control of both intermediate and final peptide preparations, including the determination of low-molecular-mass ionogenic admixtures, and the analysis of peptides in biological fluids and tissue extracts. In addition to the main applications the theoretical and methodological aspects of peptide ITP analysis are discussed. The basic electromigration properties of peptides (their polyampholyte character, effective and absolute mobilities, acid-base equilibria) are explained and the selection of parameters for peptide ITP analysis is described in detail. The advantages and disadvantages of ITP compared with other electrophoretic and chromatographic methods used for peptide analysis are discussed.
引用
收藏
页码:123 / 174
页数:52
相关论文
共 146 条
[91]   RECENT ADVANCES IN CAPILLARY ELECTROPHORESIS OF PROTEINS, PEPTIDES AND AMINO-ACIDS [J].
NOVOTNY, MV ;
COBB, KA ;
LIU, JP .
ELECTROPHORESIS, 1990, 11 (09) :735-749
[93]   FAST HORIZONTAL ELECTROPHORESIS .1. ISOELECTRIC-FOCUSING AND POLYACRYLAMIDE-GEL ELECTROPHORESIS USING PHASTSYSTEM [J].
OLSSON, I ;
AXIOFREDRIKSSON, UB ;
DEGERMAN, M ;
OLSSON, B .
ELECTROPHORESIS, 1988, 9 (01) :16-22
[94]   ISOLATION OF A PORCINE INTESTINAL PEPTIDE WITH C-TERMINAL SOMATOSTATIN [J].
PRADAYROL, L ;
CHAYVIALLE, JA ;
CARLQUIST, M ;
MUTT, V .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1978, 85 (02) :701-708
[95]   EXPERIMENTAL DEVICE FOR ELECTROKINETIC MICELLAR CHROMATOGRAPHY EXPLOITING SOME COMPONENTS OF CAPILLARY ISOTACHOPHORESIS INSTRUMENTATION [J].
PRUSIK, Z ;
KASICKA, V ;
STANEK, S ;
KUNCOVA, G ;
HAYER, M ;
VRKOC, J .
JOURNAL OF CHROMATOGRAPHY, 1987, 390 (01) :87-96
[96]   DESORPTION ISOTACHOPHORESIS AS A TOOL FOR SORBENT CHARACTERIZATION ON A MICROSCALE - A SURVEY [J].
PRUSIK, Z ;
KASICKA, V .
JOURNAL OF CHROMATOGRAPHY, 1987, 390 (01) :39-50
[97]  
PRUSIK Z, UNPUB
[98]  
PRUSIK Z, 1984, ISOTACHOPHORSIS BASI, P49
[99]  
PRUSIK Z, 1983, ELECTROPHORESIS B, P81
[100]   FLUORESCENCE EMISSION AND FLUORESCENCE QUENCHING AS DETECTION METHODS IN ISOTACHOPHORESIS [J].
REIJENGA, JC ;
VERHEGGEN, TPEM ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1984, 283 (JAN) :99-111