INFLUENCE OF PHOSPHOLIPIDIC MICROENVIRONMENT ON THE PERFORMANCE OF A POLYPYRROLE ENZYME ELECTRODE

被引:11
作者
LECA, B [1 ]
MORELIS, RM [1 ]
COULET, PR [1 ]
机构
[1] UNIV LYON 1,ESCIL,GENIE ENZYMAT LAB,CNRS,URA 1535,43 BD 11 NOVEMBRE 1918,F-69622 VILLEURBANNE,FRANCE
关键词
D O I
10.1016/0039-9140(94)E0045-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme loaded phosphatidylcholine vesicles have been introduced as a new component in the design of sensing layers for the direct coating of an amperometric transducer. For this purpose, choline oxidase was chosen as a model enzyme, and the resulting vesicles were mixed with an amphiphilic pyrrole derivative [12-(pyrrol-1-yl)dodecyltriethylammonium tetrafluoroborate]. A minute amount of this mixture was deposited and dried on a platinum electrode, then electropolymerized. Compared to a similar preparation omitting phospholipid, the sensitivity of the enzyme electrode increased from 0.06 to 0.85 mA.1.mol-1. The response, obtained in less than 20 sec, was linearly related to the choline concentration within a broader range, extending from 2.5. 10(-7) to 3. 10(-5)M.
引用
收藏
页码:925 / 930
页数:6
相关论文
共 22 条
[1]  
ASSOLANTVINET CH, 1986, ANAL LETT, V19, P875
[2]   DIFFUSION OF UNIVALENT IONS ACROSS LAMELLAE OF SWOLLEN PHOSPHOLIPIDS [J].
BANGHAM, AD ;
STANDISH, MM ;
WATKINS, JC .
JOURNAL OF MOLECULAR BIOLOGY, 1965, 13 (01) :238-+
[3]   THE TOPOGRAPHY OF ACETYLCHOLINESTERASE IN DIMYRISTOYLPHOSPHATIDYLCHOLINE LIPOSOMES [J].
BARBER, RF ;
STUHNESEKALEC, L ;
SHEK, PN ;
STANACEV, NZ .
JOURNAL OF MICROENCAPSULATION, 1989, 6 (03) :301-309
[4]  
BELANGER D, 1992, ELECTROANAL, V4, P1
[5]   AMPEROMETRIC SENSOR AND IMMOBILIZED ENZYME ELECTRODE FOR THE DETERMINATION OF ENZYMATIC-ACTIVITIES [J].
BLUM, LJ ;
BERTRAND, C ;
COULET, PR .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1983, 16 (07) :525-540
[6]   IMMOBILIZATION OF REDOX ANIONS IN POLY(AMPHIPHILIC PYRROLYLALKYLAMMONIUM) USING A SIMPLE AND MONOMER-SAVING ONE-STEP PROCEDURE IN PURE WATER-ELECTROLYTE [J].
COCHEGUERENTE, L ;
DERONZIER, A ;
GALLAND, B ;
LABBE, P ;
MOUTET, JC ;
REVERDY, G .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1991, (06) :386-388
[7]   CONTROLLED ELECTROCHEMICAL PREPARATION OF ENZYMATIC LAYERS FOR THE DESIGN OF AMPEROMETRIC BIOSENSORS [J].
COCHEGUERENTE, L ;
COSNIER, S ;
INNOCENT, C ;
MAILLEY, P ;
MOUTET, JC ;
MORELIS, RM ;
LECA, B ;
COULET, PR .
ELECTROANALYSIS, 1993, 5 (08) :647-652
[8]   MILD METHOD OF GENERAL USE FOR COVALENT COUPLING OF ENZYMES TO CHEMICALLY ACTIVATED COLLAGEN FILMS [J].
COULET, PR ;
JULLIARD, JH ;
GAUTHERON, DC .
BIOTECHNOLOGY AND BIOENGINEERING, 1974, 16 (08) :1055-1068
[9]  
COULET PR, 1992, ADV BIOSENSORS, V2, P151
[10]   CHARACTERIZATION OF THE BIOCHEMICAL BEHAVIOR OF GLUCOSE-OXIDASE ENTRAPPED IN A POLYPYRROLE FILM [J].
FORTIER, G ;
BELANGER, D .
BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (09) :854-858