ASSESSMENT OF CEREBRAL PERFUSION WITH SINGLE-PHOTON EMISSION TOMOGRAPHY IN NORMAL SUBJECTS AND IN PATIENTS WITH ALZHEIMERS-DISEASE - EFFECTS OF REGION OF INTEREST SELECTION

被引:23
作者
CLAUS, JJ
VANHARSKAMP, F
BRETELER, MMB
KRENNING, EP
VANDERCAMMEN, TJM
HOFMAN, A
HASAN, D
机构
[1] UNIV HOSP DIJKZIGT,DEPT NEUROL,3015 GD ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,SCH MED,DEPT EPIDEMIOL & BIOSTAT,3000 DR ROTTERDAM,NETHERLANDS
[3] UNIV HOSP DIJKZIGT,DEPT NUCL MED,3015 GD ROTTERDAM,NETHERLANDS
[4] UNIV HOSP DIJKZIGT,DEPT GERIATR MED,3015 GD ROTTERDAM,NETHERLANDS
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1994年 / 21卷 / 10期
关键词
ALZHEIMERS DISEASE; DEMENTIA; SINGLE-PHOTON EMISSION TOMOGRAPHY; REGION OF INTEREST;
D O I
10.1007/BF00181058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The shape, size and location of regions of interest (ROIs) show considerable variability between single-photon emission tomography (SPET) studies in aging and Alzheimer's disease, but the possible influence on study results remains unknown. We compared three different ROIs in a SPET study with 60 controls and in 48 patients with probable Alzheimer's disease diagnosed according to the NINCDS-ADRDA criteria. Regional cerebral blood flow (rCBF) nias assessed with SPET using technetium-99m d,l-hexamothylpropylene amine oxime (Tc-99m-HMPAO), normalized to the mean activity in a cerebellar reference slice. The three different ROIs were: a multi-slice and a single-slice ROI with reference to the normal brain anatomy (using an anatomical atlas), and a rectangular (2x4 pixels) ROI in the frontal, temporal, temporoparietal and occipital cortices. No differences were observed for the means of rCBF values between the single-slice and multi-slice ROI's with reference to the normal anatomy, but some variability was present for individual comparisons. In contrast, significantly higher mean rCBF values were obtained with the single-slice rectangular ROIs in all four regions for both patients and controls and considerable variability was shown for individual subjects. After analysis with multivariate logistic regression and receiver operator characteristic curves, the ability of SPET to discriminate between controls and Alzheimer patients was similar in the three methods for mild and moderate Alzheimer patients (Global Deterioration Scale = GDS of 3 and 4). However, with increasing dementia severity (GDS>4) the rectangular ROIs showed lower ability to discriminate between groups compared to the single-slice and multi-slice anatomically defined ROIs. This study suggests that results of rCBF assessment with SPET using Tc-99m-HMPAO in patients with seven Alzheimer's disease are influenced by the shape and size of the ROI.
引用
收藏
页码:1044 / 1051
页数:8
相关论文
共 36 条
[11]   SELECTION AND INTERPRETATION OF DIAGNOSTIC-TESTS AND PROCEDURES - PRINCIPLES AND APPLICATIONS [J].
GRINER, PF ;
MAYEWSKI, RJ ;
MUSHLIN, AI ;
GREENLAND, P .
ANNALS OF INTERNAL MEDICINE, 1981, 94 (04) :553-+
[12]   A COMPARATIVE TC-99M HEXAMETHYLPROPYLENE AMINE OXIME SPET STUDY IN DIFFERENT TYPES OF DEMENTIA [J].
HABERT, MO ;
SPAMPINATO, U ;
MAS, JL ;
PIKETTY, ML ;
BOURDEL, MC ;
DERECONDO, J ;
RONDOT, P ;
ASKIENAZY, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (01) :3-11
[13]   SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH ACUTE HYDROCEPHALUS OR WITH CEREBRAL-ISCHEMIA AFTER SUBARACHNOID HEMORRHAGE [J].
HASAN, D ;
VANPESKI, J ;
LOEVE, I ;
KRENNING, EP ;
VERMEULEN, M .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1991, 54 (06) :490-493
[14]   DETERMINANTS OF DISEASE AND DISABILITY IN THE ELDERLY - THE ROTTERDAM ELDERLY STUDY [J].
HOFMAN, A ;
GROBBEE, DE ;
DEJONG, PTVM ;
VANDENOUWELAND, FA .
EUROPEAN JOURNAL OF EPIDEMIOLOGY, 1991, 7 (04) :403-422
[15]  
HOLMAN BL, 1992, J NUCL MED, V33, P181
[16]   SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY USING TC-99M-HMPAO IN THE ROUTINE EVALUATION OF ALZHEIMERS-DISEASE [J].
HURWITZ, TA ;
AMMANN, W ;
CHU, D ;
CLARK, C ;
HOLDEN, J ;
BROWNSTONE, R .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1991, 18 (01) :59-62
[17]  
JACKSON D, 1992, BMDP STATISTICAL SOF, V2, P989
[18]  
JENNRICH R, 1992, BMDP STATISTICAL SOF, V1, P521
[19]   CEREBRAL PERFUSION IMAGING IN ALZHEIMERS-DISEASE - USE OF SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY AND IOFETAMINE HYDROCHLORIDE-I-123 [J].
JOHNSON, KA ;
MUELLER, ST ;
WALSHE, TM ;
ENGLISH, RJ ;
HOLMAN, BL .
ARCHIVES OF NEUROLOGY, 1987, 44 (02) :165-168
[20]  
LEAR JL, 1988, J NUCL MED, V29, P1387