EFFECT OF A SPACER ON PULMONARY AEROSOL DEPOSITION FROM A JET NEBULIZER DURING MECHANICAL VENTILATION

被引:41
作者
HARVEY, CJ
ODOHERTY, MJ
PAGE, CJ
THOMAS, SHL
NUNAN, TO
TREACHER, DF
机构
[1] UNITED MED & DENT SCH,ST THOMAS HOSP,DEPT NUCL MED,LONDON SE1 7EH,ENGLAND
[2] UNITED MED & DENT SCH,ST THOMAS HOSP,INTENS THERAPY UNIT,LONDON SE1 7EH,ENGLAND
[3] UNIV NEWCASTLE UPON TYNE,WOLFSON DEPT CLIN PHARMACOL,NEWCASTLE TYNE NE1 7RU,TYNE & WEAR,ENGLAND
关键词
VENTILATOR; AEROSOL; NEBULIZER;
D O I
10.1136/thx.50.1.50
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background - Several factors have been identified which improve nebulised aerosol delivery in vitro. One of these is the addition of a spacer to the ventilator circuit which improves aerosol delivery from a jet nebuliser to a model lung by approximately 30%. The current study was designed to demonstrate whether similar improvements could be demonstrated in vivo. Methods - Ten patients (seven men) were studied during mechanical ventilation (Siemens Servo 900C) after open heart surgery. Aerosol was delivered using a Siemens Servo 945 nebuliser system (high setting) driving a System 22 Acorn jet nebuliser (Medic-Aid) containing 3 ml technetium-99m labelled human serum albumin (Tc-99m-HSA (50 mu g); activity in the first nebulisation, 90 MBq; in the second nebulisation, 185 MBq). Central and peripheral lung aerosol deposition and the time to complete deposition were measured using a gamma camera and compared when the nebuliser was connected to the inspiratory limb using a simple T-piece or a 600 ml spacer. Results - The addition of the spacer increased total lung deposition (mean (SD) percentage initial nebuliser activity) from 2.2 (0.7)% to 3 (0.8)%. There was no difference in the time required to complete nebulisation (18.2 min v 18.3 min respectively for T-piece and spacer) or in the retention of activity in the nebuliser (46.2% v 47.1% respectively). Conclusions - The combination of a spacer with a jet nebuliser increased lung deposition by 36% in mechanically ventilated patients and is a simple way of increasing drug deposition or reducing the amount of an expensive drug required for nebulisation.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 11 条
[1]   PRESSURIZED AEROSOL VERSUS JET AEROSOL DELIVERY TO MECHANICALLY VENTILATED PATIENTS - COMPARISON OF DOSE TO THE LUNGS [J].
FULLER, HD ;
DOLOVICH, MB ;
POSMITUCK, G ;
PACK, WW ;
NEWHOUSE, MT .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (02) :440-444
[2]   AEROSOL DELIVERY IN INTUBATED, MECHANICALLY VENTILATED PATIENTS [J].
MACINTYRE, NR ;
SILVER, RM ;
MILLER, CW ;
SCHULER, F ;
COLEMAN, RE .
CRITICAL CARE MEDICINE, 1985, 13 (02) :81-84
[3]   IMPROVEMENT OF PRESSURISED AEROSOL DEPOSITION WITH NEBUHALER SPACER DEVICE [J].
NEWMAN, SP ;
MILLAR, AB ;
LENNARDJONES, TR ;
MOREN, F ;
CLARKE, SW .
THORAX, 1984, 39 (12) :935-941
[4]  
NEWMAN SP, 1981, AM REV RESPIR DIS, V124, P317
[5]   DELIVERY OF A NEBULIZED AEROSOL TO A LUNG MODEL DURING MECHANICAL VENTILATION - EFFECT OF VENTILATOR SETTINGS AND NEBULIZER TYPE, POSITION, AND VOLUME OF FILL [J].
ODOHERTY, MJ ;
THOMAS, SHL ;
PAGE, CJ ;
TREACHER, DF ;
NUNAN, TO .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 146 (02) :383-388
[6]   AEROSOL DEPOSITION IN MECHANICALLY VENTILATED PATIENTS - OPTIMIZING NEBULIZER DELIVERY [J].
ORIORDAN, TG ;
PALMER, LB ;
SMALDONE, GC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (01) :214-219
[7]   NEBULIZER FUNCTION DURING MECHANICAL VENTILATION [J].
ORIORDAN, TG ;
GRECO, MJ ;
PERRY, RJ ;
SMALDONE, GC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (05) :1117-1122
[8]  
THOMAS SHL, 1988, LANCET, V1, P126
[9]   PULMONARY DEPOSITION OF A NEBULIZED AEROSOL DURING MECHANICAL VENTILATION [J].
THOMAS, SHL ;
ODOHERTY, MJ ;
FIDLER, HM ;
PAGE, CJ ;
TREACHER, DF ;
NUNAN, TO .
THORAX, 1993, 48 (02) :154-159
[10]   DELIVERY OF ULTRASONIC NEBULIZED AEROSOLS TO A LUNG MODEL DURING MECHANICAL VENTILATION [J].
THOMAS, SHL ;
ODOHERTY, MJ ;
PAGE, CJ ;
TREACHER, DF ;
NUNAN, TO .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (04) :872-877