QUANTITATIVE ECHO CONTRAST CONCENTRATION MEASUREMENT BY DOPPLER SONOGRAPHY

被引:47
作者
SCHWARZ, KQ
BEZANTE, GP
CHEN, XC
SCHLIEF, R
机构
[1] UNIV ROCHESTER,CTR BIOMED ULTRASOUND,ROCHESTER,NY 14642
[2] SCHERING AG,MAGNET RESONANCE & ULTRASOUND CONTRAST MEDIA,W-1000 BERLIN,GERMANY
关键词
DOPPLER ULTRASOUND; CONTRAST ECHOCARDIOGRAPHY; ULTRASOUND SCATTERING;
D O I
10.1016/0301-5629(93)90101-S
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The hypothesis investigated in this study is that Doppler ultrasound can be used to make quantitative echo contrast concentration measurements in flow systems. Our motivation was to demonstrate the utility and some of the pitfalls of using scattered ultrasound intensity to quantify echo contrast in chambers and vessels. Doppler ultrasound was used rather than conventional imaging techniques because of its natural association with the assessment of flow in chambers and vessels. We compared the intensity of audio Doppler to various steady-state concentrations echo contrast in a carefully controlled in vitro flow system. A total of 62 paired audio Doppler intensity and echo contrast concentration measurements were made. A weak positive correlation was found between the absolute echo contrast concentration and audio Doppler intensity (r = 0.510, p = 0.001).The correlation was weak because of the many unknowns and effervescent nature of microbubble echo contrast agents. However, audio Doppler intensity was shown to correlate strongly with the relative concentration of echo contrast over short time periods (r = 0.958, p = 0.0001). The results show that Doppler intensity can be used to quantitatively measure the relative, but not the absolute concentration of echo contrast in in vitro flow systems.
引用
收藏
页码:289 / 297
页数:9
相关论文
共 23 条
[1]   ULTRASONIC CHARACTERIZATION OF ALBUNEX, A NEW CONTRAST AGENT [J].
BLEEKER, HJ ;
SHUNG, KK ;
BARNHART, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (04) :1792-1797
[2]  
BOMMER W, 1981, CIRCULATION, V4, P203
[3]   GELATIN ENCAPSULATED NITROGEN MICROBUBBLES AS ULTRASONIC CONTRAST AGENTS [J].
CARROLL, BA ;
TURNER, RJ ;
TICKNER, EG ;
BOYLE, DB ;
YOUNG, SW .
INVESTIGATIVE RADIOLOGY, 1980, 15 (03) :260-266
[4]  
ERNST A, 1988, J CARDIOVASC ULTRAS, V7, P329
[5]  
ERNST A, 1984, Journal of Cardiovascular Ultrasonography, V3, P143
[6]   HYDROGEN-PEROXIDE CONTRAST ECHOCARDIOGRAPHY [J].
GAFFNEY, FA ;
LIN, JC ;
PESHOCK, RM ;
BUSH, L ;
BUJA, LM .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (05) :607-609
[7]   VALUE OF IMAGE-ENHANCEMENT AND INJECTION OF CONTRAST-MEDIUM FOR RIGHT VENTRICULAR VOLUME DETERMINATION BY 2-DIMENSIONAL ECHOCARDIOGRAPHY IN CONGENITAL HEART-DISEASE [J].
LANGE, PE ;
SEIFFERT, PA ;
PRIES, F ;
WESSEL, A ;
ONNASCH, DGW ;
HAHNE, HJ ;
HEINTZEN, PH .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (01) :152-157
[8]   MICROBUBBLES HAVE INTRACARDIAC VELOCITIES SIMILAR TO THOSE OF RED-BLOOD-CELLS [J].
LEVINE, RA ;
TEICHHOLZ, LE ;
GOLDMAN, ME ;
STEINMETZ, MY ;
BAKER, M ;
MELTZER, RS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :28-33
[9]  
Matsuda M, 1983, J Cardiogr, V13, P1021
[10]   INTRAVENOUS CARBON-DIOXIDE AS AN ECHOCARDIOGRAPHIC CONTRAST AGENT [J].
MELTZER, RS ;
SERRUYS, PW ;
HUGENHOLTZ, PG ;
ROELANDT, J .
JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (03) :127-131