QUANTITATIVE ECHO CONTRAST CONCENTRATION MEASUREMENT BY DOPPLER SONOGRAPHY

被引:47
作者
SCHWARZ, KQ
BEZANTE, GP
CHEN, XC
SCHLIEF, R
机构
[1] UNIV ROCHESTER,CTR BIOMED ULTRASOUND,ROCHESTER,NY 14642
[2] SCHERING AG,MAGNET RESONANCE & ULTRASOUND CONTRAST MEDIA,W-1000 BERLIN,GERMANY
关键词
DOPPLER ULTRASOUND; CONTRAST ECHOCARDIOGRAPHY; ULTRASOUND SCATTERING;
D O I
10.1016/0301-5629(93)90101-S
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The hypothesis investigated in this study is that Doppler ultrasound can be used to make quantitative echo contrast concentration measurements in flow systems. Our motivation was to demonstrate the utility and some of the pitfalls of using scattered ultrasound intensity to quantify echo contrast in chambers and vessels. Doppler ultrasound was used rather than conventional imaging techniques because of its natural association with the assessment of flow in chambers and vessels. We compared the intensity of audio Doppler to various steady-state concentrations echo contrast in a carefully controlled in vitro flow system. A total of 62 paired audio Doppler intensity and echo contrast concentration measurements were made. A weak positive correlation was found between the absolute echo contrast concentration and audio Doppler intensity (r = 0.510, p = 0.001).The correlation was weak because of the many unknowns and effervescent nature of microbubble echo contrast agents. However, audio Doppler intensity was shown to correlate strongly with the relative concentration of echo contrast over short time periods (r = 0.958, p = 0.0001). The results show that Doppler intensity can be used to quantitatively measure the relative, but not the absolute concentration of echo contrast in in vitro flow systems.
引用
收藏
页码:289 / 297
页数:9
相关论文
共 23 条
[11]   TRANSMISSION OF ULTRASONIC CONTRAST THROUGH THE LUNGS [J].
MELTZER, RS ;
SARTORIUS, OEH ;
LANCEE, CT ;
SERRUYS, PW ;
VERDOUW, PD ;
ESSED, CE ;
ROELANDT, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (04) :377-384
[12]  
Nemec J J, 1991, J Am Soc Echocardiogr, V4, P79
[13]   CONTRAST AGENTS IN DIAGNOSTIC ULTRASOUND [J].
OPHIR, J ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04) :319-333
[14]   ULTRASOUND CONTRAST FOR HEPATIC-TUMORS USING IDE PARTICLES [J].
PARKER, KJ ;
BAGGS, RB ;
LERNER, RM ;
TUTHILL, TA ;
VIOLANTE, MR .
INVESTIGATIVE RADIOLOGY, 1990, 25 (10) :1135-1139
[15]  
REISNER SA, 1988, J CARDIOVASC ULTRAS, V7, P273
[16]   CONTRAST ECHO WASHOUT CURVES FROM THE LEFT-VENTRICLE - APPLICATION OF BASIC PRINCIPLES OF INDICATOR-DILUTION THEORY AND CALCULATION OF EJECTION FRACTION [J].
ROVAI, D ;
NISSEN, SE ;
ELION, J ;
SMITH, M ;
LABBATE, A ;
KWAN, OL ;
DEMARIA, AN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (01) :125-134
[17]  
SCHLIEF R, 1991, CURR OPIN RADIOL, V3, P198
[18]  
SHANDAS TR, 1990, CIRCULATION, V82, P111
[19]   SUPERIOR INTENSITY AND REPRODUCIBILITY OF SHU-454, A NEW RIGHT HEART CONTRAST AGENT [J].
SMITH, MD ;
KWAN, OL ;
REISER, HJ ;
DEMARIA, AN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (04) :992-998
[20]  
TORES F, 1989, J AM SOC ECHOCARDIOG, V2, P419