CARDIAC INDEX QUANTIFICATION BY DOPPLER ULTRASOUND IN PATIENTS WITHOUT LEFT-VENTRICULAR OUTFLOW TRACT ABNORMALITIES

被引:63
作者
EVANGELISTA, A
GARCIADORADO, D
DELCASTILLO, HG
GONZALEZALUJAS, T
SOLERSOLER, J
机构
[1] Servei de Cardiologia, Hospital General Universitari Vall d'Hebron. Barcelona
关键词
D O I
10.1016/0735-1097(94)00456-Z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We attempted to ascertain whether cardiac index can be directly es Background. Although diverse Doppler echocardiographic methods have been described for cardiac output quantification, they are not widely used in clinical practice. Cross-sectional area measurement has been identified as the main source of error in flow volume quantification. Methods. A three-phase study by Doppler echocardiography was conducted in 306 patients. In phase I, the normal mean velocity ratio of the left and right ventricular outflow tracts was established in 170 normal subjects. In phase II, cardiac index, calculated as the product of aortic annular area index by mean velocity (conventional method), and mean velocity determined in the left ventricular outflow tract and ascending aorta by pulsed and continuous wave Doppler, respectively, were correlated with thermodilution cardiac index in 66 patients. In phase III, the accuracy of the regression equations obtained was prospectively assessed in an additional 70 patients. Results. The normal left/right ventricular outflow tract mean velocity ratio by pulsed wave Doppler was 1.1 +/- 0.1. Cardiac index (CI) calculated by the conventional method and thermodilution (TD) showed acceptable correlation (r = 0.90, CITD = 1.20 CIPWD + 357; r = 0.86, CITD = 0.90 CICWD + 262) for pulsed (PWD) and continuous wave (CWD) Doppler, respectively, but with systematic underestimation (- 28 +/- 13%, p < 0.01) by pulsed wave Doppler. Mean velocity (MV showed excellent correlation with the thermodilution cardiac index (r = 0.97, CITD = 172 MV(PWD) - 172; r = 0.93, CITD = 129 MV(CWD) - 255). When these regression equations were prospectively applied, better agreement with the thermodilution cardiac index was obtained by pulsed wave Doppler directly from mean velocity (SD 240 ml/min per m(2)) than when aortic annular area was considered in the calculation (SD 428 ml/min per m(2)). Similar results were obtained by continuous wave Doppler (SD 433 vs. 599 ml/min per m(2)) but with less accuracy. Conclusions. Left ventricular outflow tract mean velocity determined by pulsed wave Doppler permits easy, accurate cardiac index quantification in the absence of left ventricular outflow abnormalities. The simplicity of this method enhances its clinical applicability in noninvasive monitoring of cardiac index.
引用
收藏
页码:710 / 716
页数:7
相关论文
共 41 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   MEASUREMENT OF LEFT-VENTRICULAR STROKE VOLUME USING CONTINUOUS WAVE DOPPLER ECHOCARDIOGRAPHY OF THE ASCENDING AORTA AND M-MODE ECHOCARDIOGRAPHY OF THE AORTIC-VALVE [J].
BOUCHARD, A ;
BLUMLEIN, S ;
SCHILLER, NB ;
SCHLITT, S ;
BYRD, BF ;
PORTS, T ;
CHATTERJEE, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (01) :75-83
[3]   DETERMINATION OF STROKE VOLUME AND CARDIAC-OUTPUT DURING EXERCISE - COMPARISON OF TWO-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHY, FICK OXIMETRY, AND THERMODILUTION [J].
CHRISTIE, J ;
SHELDAHL, LM ;
TRISTANI, FE ;
SAGAR, KB ;
PTACIN, MJ ;
WANN, S .
CIRCULATION, 1987, 76 (03) :539-547
[4]   DOPPLER ULTRASONIC MEASUREMENT OF CARDIAC-OUTPUT - REPRODUCIBILITY AND VALIDATION [J].
COATS, AJS .
EUROPEAN HEART JOURNAL, 1990, 11 :49-61
[5]   A DOPPLER ECHOCARDIOGRAPHIC EXAMINATION OF THE NORMAL AORTIC-VALVE AND LEFT-VENTRICULAR OUTFLOW TRACT [J].
DAVIDSON, WR ;
PASQUALE, MJ ;
FANELLI, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (06) :547-549
[6]   INFLUENCE OF SAMPLING SITE AND FLOW AREA ON CARDIAC-OUTPUT MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY [J].
DITTMANN, H ;
VOELKER, W ;
KARSCH, KR ;
SEIPEL, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :818-823
[7]   COMPARATIVE ACCURACY OF DOPPLER ECHOCARDIOGRAPHIC METHODS FOR CLINICAL STROKE VOLUME DETERMINATION [J].
DUBIN, J ;
WALLERSON, DC ;
CODY, RJ ;
DEVEREUX, RB .
AMERICAN HEART JOURNAL, 1990, 120 (01) :116-123
[8]  
ELHABBAL M, 1989, AM J CARDIOL, V63, P322
[9]   THE USE OF DOPPLER FLOW VELOCITY-MEASUREMENT TO ASSESS THE HEMODYNAMIC-RESPONSE TO VASODILATORS IN PATIENTS WITH HEART-FAILURE [J].
ELKAYAM, U ;
GARDIN, JM ;
BERKLEY, R ;
HUGHES, CA ;
HENRY, WL .
CIRCULATION, 1983, 67 (02) :377-383
[10]   DETERMINATION OF CARDIAC-OUTPUT BY SINGLE GATED PULSED DOPPLER ECHOCARDIOGRAPHY [J].
FAST, JH ;
VANDENMERKHOF, L ;
BLANS, W ;
VANLEEUWEN, K ;
UIJEN, G .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1988, 21 (01) :33-42