EFFECT OF BALLOON ANGIOPLASTY ON FEMORAL-ARTERY EVALUATED WITH INTRAVASCULAR ULTRASOUND IMAGING

被引:87
作者
THE, SHK
GUSSENHOVEN, EJ
ZHONG, Y
LI, WG
VANEGMOND, F
PIETERMAN, H
VANURK, H
GERRITSEN, GP
BORST, C
WILSON, RA
BOM, N
机构
[1] ERASMUS UNIV,THORAXCTR,EE 2312,POB 1738,3000 DR ROTTERDAM,NETHERLANDS
[2] INTERUNIV CARDIOL INST,UTRECHT,NETHERLANDS
[3] ERASMUS UNIV,DEPT RADIOL,3000 DR ROTTERDAM,NETHERLANDS
[4] ERASMUS UNIV,DEPT VASC SURG,3000 DR ROTTERDAM,NETHERLANDS
[5] UNIV UTRECHT HOSP,DEPT CARDIOL,3511 GV UTRECHT,NETHERLANDS
关键词
ARTERIES; ULTRASOUND IMAGING; INTRAVASCULAR; ATHEROSCLEROSIS; BALLOON ANGIOPLASTY;
D O I
10.1161/01.CIR.86.2.483
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Intravascular ultrasound was used to assess the immediate effect of balloon angioplasty on the superficial femoral artery. Methods and Results. In 16 consecutive patients, corresponding ultrasonic cross sections (n=72) before and after balloon angioplasty were qualitatively and quantitatively analyzed. The qualitative data were compared with angiographic findings. Before intervention, the angiographically demonstrated obstructive lesions were confirmed by intravascular ultrasound. Ultrasound enabled discrimination between soft (n=43) and hard (n=29) lesions, as well as between eccentric (n=57) and concentric (n=15) lesions. After balloon angioplasty, the presence of a dissection assessed angiographically in 14 patients was confirmed by intravascular ultrasound. Additional morphological information provided by ultrasound included plaque rupture in 14 patients and internal lamina rupture in six patients. Quantitative ultrasound data revealed an increase in free lumen area from 9.7+/-4.7 to 18.3+/-7.0 mm2 (p less-than-or-equal-to 0.01), an increase in minimal lumen diameter from 2.8+/-0.7 to 3.6+/-1.2 mm (p less-than-or-equal-to 0.01), and an increase in media-bounded area from 21.7+/-5.4 to 28.3+/-5.8 mm2 (p less-than-or-equal-to 0.01). The lesion area for the majority of cases (n=32) remained unchanged (13.0+/-4.9 mm2 versus 12.9+/-4.6 mm2), or the lesion disappeared partially (from 9.1+/-0.9 to 4.3+/-1.4 mm2, n=4, p less-than-or-equal-to 0.01) or totally (from 10.1+/-4.2 to 0 mm2, n=6). Stretching of the arterial wall was further evidenced by medial thinning from 0.55+/-0.19 to 0.34+/-0.11 mm (p less-than-or-equal-to 0.01). Conclusions. Luminal enlargement by balloon dilatation is achieved primarily by overstretching the arterial wall, with the lesion volume remaining practically unchanged. Overstretching is accompanied almost always by dissection and plaque rupture and occasionally by an internal lamina rupture.
引用
收藏
页码:483 / 493
页数:11
相关论文
共 33 条
  • [21] LOSORDO DW, 1990, CIRCULATION, V82, P338
  • [22] VESSEL, PLAQUE, AND LUMEN MORPHOLOGY AFTER TRANS-LUMINAL BALLOON ANGIOPLASTY - QUANTITATIVE STUDY IN DISTENDED HUMAN ARTERIES
    LYON, RT
    ZARINS, CK
    LU, CT
    YANG, CF
    GLAGOV, S
    [J]. ARTERIOSCLEROSIS, 1987, 7 (03): : 306 - 314
  • [23] INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION
    NISHIMURA, RA
    EDWARDS, WD
    WARNES, CA
    REEDER, GS
    HOLMES, DR
    TAJIK, AJ
    YOCK, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) : 145 - 154
  • [24] REAL-TIME INTRAVASCULAR ULTRASOUND IMAGING IN HUMANS
    PANDIAN, NG
    KREIS, A
    WEINTRAUB, A
    MOTARJEME, A
    DESNOYERS, M
    ISNER, JM
    KONSTAM, M
    SALEM, DN
    MILLEN, V
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (20) : 1392 - 1396
  • [25] CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND
    POTKIN, BN
    BARTORELLI, AL
    GESSERT, JM
    NEVILLE, RF
    ALMAGOR, Y
    ROBERTS, WC
    LEON, MB
    [J]. CIRCULATION, 1990, 81 (05) : 1575 - 1585
  • [26] Tobis J M, 1991, Int J Card Imaging, V6, P191, DOI 10.1007/BF01797851
  • [27] INTRAVASCULAR ULTRASOUND CROSS-SECTIONAL ARTERIAL IMAGING BEFORE AND AFTER BALLOON ANGIOPLASTY INVITRO
    TOBIS, JM
    MALLERY, JA
    GESSERT, J
    GRIFFITH, J
    MAHON, D
    BESSEN, M
    MORIUCHI, M
    MCLEAY, L
    MCRAE, M
    HENRY, WL
    [J]. CIRCULATION, 1989, 80 (04) : 873 - 882
  • [28] INTRAVASCULAR ULTRASOUND IMAGING OF HUMAN CORONARY-ARTERIES INVIVO - ANALYSIS OF TISSUE CHARACTERIZATIONS WITH COMPARISON TO INVITRO HISTOLOGICAL SPECIMENS
    TOBIS, JM
    MALLERY, J
    MAHON, D
    LEHMANN, K
    ZALESKY, P
    GRIFFITH, J
    GESSERT, J
    MORIUCHI, M
    MCRAE, M
    DWYER, ML
    GREEP, N
    HENRY, WL
    [J]. CIRCULATION, 1991, 83 (03) : 913 - 926
  • [29] VANOTTERLOO PJ, 1988, THESIS DELFT U TECHN, P25
  • [30] VLODAVER Z, 1971, Progress in Cardiovascular Diseases, V14, P256, DOI 10.1016/0033-0620(71)90023-5