3-DIMENSIONAL THEORETICAL TEMPERATURE DISTRIBUTIONS PRODUCED BY 915-MHZ DIPOLE ANTENNA-ARRAYS WITH VARYING INSERTION DEPTHS IN MUSCLE-TISSUE

被引:6
作者
MECHLING, JA
STROHBEHN, JW
RYAN, TP
机构
[1] DARTMOUTH COLL,THAYER SCH ENGN,HANOVER,NH 03755
[2] DARTMOUTH COLL,HITCHCOCK MED CTR,HANOVER,NH 03756
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1992年 / 22卷 / 01期
关键词
FINITE ELEMENTS; HYPERTHERMIA; INSERTION DEPTH; MICROWAVE ANTENNAS; TEMPERATURE DISTRIBUTIONS;
D O I
10.1016/0360-3016(92)90992-Q
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Interstitial microwave antenna array hyperthermia (IMAAH) systems are currently being used in the treatment of cancer. The insertion depth of an interstitial microwave antenna, defined as the length of the antenna from the tip to the point of insertion in tissue, affects its ability to produce uniform power deposition patterns in tumor volumes. The effect of varying insertion depths on the ability of an IMAAH system to heat two theoretical tumor models was examined. Four dipole microwave antennas were implanted in a 2 x 2 cm array and driven at 915 MHz in muscle tissue. The explicit power deposition patterns were calculated for each insertion depth using known theory. The bioheat transfer equation was solved for the 3-dimensional steady-state temperature distributions in cylindrical and ellipsoidal tumor models using a finite element method. Homogeneous and nonhomogeneous blood flow models were considered. As a basis of comparison of the various temperature distributions, the volume of tumor heated to greater-than-or-equal-to 43-degrees-C was calculated. Under the conditions of this study, the insertion depth was shown to have a significant effect on the ability of an IMAAH system to heat the tumor volumes. A sharp decrease in the percentage of tumor volume heated to greater-than-or-equal-to 43-degrees-C was seen for insertion depths between 7.8 and 14.6 cm. At an insertion depth of 11.7 cm (3/4-lambda) there was virtually no heating of the tumor. Regions of elevated power occurred outside of the desired treatment volume, stressing the importance of adequate thermometry techniques and demonstrating the need for hyperthermia treatment planning prior to implantation of an antenna array. Plots of the power deposition patterns and the corresponding temperatures produced in the diagonal plane of the antenna arrays are present.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 38 条
[31]  
TREMBLY BS, 1991, HYPERTHERMIA ONCOLOG, V3, P11
[32]  
TREMBLY BS, 1985, IEEE T BIOMED ENG, V35, P152
[33]   SAR PATTERNS FROM AN INTERSTITIAL MICROWAVE ANTENNA-ARRAY HYPERTHERMIA SYSTEM [J].
WONG, TZ ;
STROHBEHN, JW ;
JONES, KM ;
MECHLING, JA ;
TREMBLY, BS .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :560-567
[34]  
WONG TZ, 1991, IN PRESS INT J HYPER
[35]   THE DETERMINATION OF THE ELECTROMAGNETIC-FIELD AND SAR PATTERN OF AN INTERSTITIAL APPLICATOR IN A DISSIPATIVE DIELECTRIC MEDIUM [J].
ZHANG, Y ;
DUBAL, NV ;
TAKEMOTOHAMBLETON, R ;
JOINES, WT .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1988, 36 (10) :1438-1444
[36]  
Zienkiewicz O. C., 1977, FINITE ELEMENT METHO
[37]  
[No title captured]
[38]  
[No title captured]