MODIFIER ADDITION IN MICROCOLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH A HIGH-PRESSURE PULSED VALVE

被引:15
作者
FRANCIS, ES
LEE, ML
RICHTER, BE
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM,PROVO,UT 84602
[2] DIONEX CHEM CORP,SALT LAKE CITY,UT 84119
关键词
SUPERCRITICAL FLUID CHROMATOGRAPHY; MIXED MOBILE PHASES; METHANOL MODIFIED CARBON DIOXIDE; PULSED VALVE;
D O I
10.1002/mcs.1220060504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The need for mixed mobile phases at low flow rates suitable for capillary and packed capillary supercritical fluid chromatography (SFC) has led to the use of an air actuated high pressure prime/purge valve for on-line modifier introduction. This valve can consistently deliver small amounts of modifier into the mobile phase, and allows rapid changes of modifier concentrations. Methanol modified carbon dioxide(CO2), from 0.5 to 15 mole percent, has been generated using this valve at a flow rate compatible with a packed capillary column without the need for flow splitting. Two instrumental configurations were used to evaluate the valve. One configuration used separate pumps for the mobile phase and the modifier. The other configuration used only one pump with a pneumatic amplifier as the modifier reservoir. The valve provides reproducible modifier concentrations, percent relative standard deviation (%RSD) for retention times less than 2%, and dependable use, leak free after > 250,000 pulses. The use of this valve, with both the 2-pump and 1-pump/pneumatic amplifier configuration is demonstrated. The effects of modifier addition on the retention times of components in several samples are shown.
引用
收藏
页码:449 / 457
页数:9
相关论文
共 16 条
[1]  
ALLINGTON RW, 1989, Patent No. 4882063
[2]  
ANTON K, 1989, HRC-J HIGH RES CHROM, V12, P394
[3]   ROLE OF ADDITIVES IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY - SUPPRESSION OF SOLUTE IONIZATION [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2) :377-392
[4]  
CROOK P, 1990, METALS HDB, V2, P446
[5]  
Crook P., 1992, ASM HDB, V18, P766
[6]   CHARACTERIZATION OF THE NITROGEN AND PHOSPHORUS THERMIONIC DETECTOR RESPONSE IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
DAVID, PA ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2082-2086
[7]   ULTRAVIOLET-ABSORPTION DETECTOR FOR CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY WITH COMPRESSIBLE MOBILE PHASES [J].
FIELDS, SM ;
MARKIDES, KE ;
LEE, ML .
ANALYTICAL CHEMISTRY, 1988, 60 (08) :802-806
[8]   SOME ASPECTS OF CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
JANSSEN, HG ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1990, 505 (01) :19-35
[9]   PREPARATION OF LONG PACKED CAPILLARY COLUMNS USING CARBON-DIOXIDE SLURRIES [J].
MALIK, A ;
LI, WB ;
LEE, ML .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (04) :361-369
[10]   PRESSURE AND MODIFIER PROGRAMMING IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
MORRISSEY, MA ;
GIORGETTI, A ;
POLASEK, M ;
PERICLES, N ;
WIDMER, HM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :237-242