OBJECTIVE. The purpose of this study was to compare the cost of unenhanced MR imaging with that of CT with high- or low-osmolality contrast agents for abdominal or pelvic imaging in patients at risk for nephrotoxic effects induced by contrast material. MATERIALS AND METHODS. Using decision analysis, we evaluated direct medical care costs associated with the use of CT with high- or low-osmolality contrast agents vs MR imaging. We used data from a variety of sources and assumed that the three imaging techniques provide nearly equivalent diagnostic information. The base-case analysis assumed that patients were at low risk (i.e., 2%) for development of nephrotoxic effects. Nephrotoxic effects were defined as increases in the serum level of creatinine of 50% or more above baseline. Our analysis took the perspective of the hospital and used estimated hospital costs, not charges. Sensitivity analyses were performed on risk estimates for development of nephrotoxic effects and for the estimates of medical care costs. RESULTS. For the base case, CT with a high-osmolality contrast agent is the least costly imaging strategy. When the risk of nephrotoxic effects exceeds 5% for high-osmolality contrast agents or 2.6% for low-osmolality contrast agents, then MR imaging is the preferred strategy, The model is relatively insensitive to treatment costs. CONCLUSION. From a hospital's perspective, MR imaging of the abdomen or pelvis is cost minimizing in patients at high risk for nephrotoxic effects induced by contrast agents. Use of tow-osmolality contrast agents must reduce the frequency of nephrotoxic effects in high-risk patients by at least 50% to be less costly than MR imaging.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 20 条
[1]  
Arrigo G, 1987, Contrib Nephrol, V55, P176
[2]   CONTRAST NEPHROPATHY IN PATIENTS WITH IMPAIRED RENAL-FUNCTION - HIGH VERSUS LOW OSMOLAR MEDIA [J].
BARRETT, BJ ;
PARFREY, PS ;
VAVASOUR, HM ;
MCDONALD, J ;
KENT, G ;
HEFFERTON, D ;
ODEA, F ;
STONE, E ;
REDDY, R ;
MCMANAMON, PJ .
KIDNEY INTERNATIONAL, 1992, 41 (05) :1274-1279
[3]   METAANALYSIS OF THE RELATIVE NEPHROTOXICITY OF HIGH-OSMOLALITY AND LOW-OSMOLALITY IODINATED CONTRAST-MEDIA [J].
BARRETT, BJ ;
CARLISLE, EJ .
RADIOLOGY, 1993, 188 (01) :171-178
[4]   A CLOSER LOOK AT RADIOCONTRAST-INDUCED NEPHROPATHY [J].
BREZIS, M ;
EPSTEIN, FH .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (03) :179-181
[5]   PERFLUOROCTYLBROMIDE AS A GASTROINTESTINAL CONTRAST AGENT FOR MR IMAGING - USE WITH AND WITHOUT GLUCAGON [J].
BROWN, JJ ;
DUNCAN, JR ;
HEIKEN, JP ;
BALFE, DM ;
CORR, AP ;
MIROWITZ, SA ;
EILENBERG, SS ;
LEE, JKT .
RADIOLOGY, 1991, 181 (02) :455-460
[6]   THE RISKS OF DEATH AND OF SEVERE NONFATAL REACTIONS WITH HIGH-OSMOLALITY VS LOW-OSMOLALITY CONTRAST-MEDIA - A METAANALYSIS [J].
CARO, JJ ;
TRINDADE, E ;
MCGREGOR, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (04) :825-832
[7]   THE COST-EFFECTIVENESS OF REPLACING HIGH-OSMOLALITY WITH LOW-OSMOLALITY CONTRAST-MEDIA [J].
CARO, JJ ;
TRINDADE, E ;
MCGREGOR, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) :869-874
[8]   APPLYING COST-EFFECTIVENESS ANALYSIS - THE INSIDE STORY [J].
EDDY, DM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (18) :2575-2582
[9]   MEDICAL PROGRESS .2. MAGNETIC-RESONANCE-IMAGING [J].
EDELMAN, RR ;
WARACH, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (11) :785-791
[10]   MEDICAL PROGRESS .1. MAGNETIC-RESONANCE-IMAGING [J].
EDELMAN, RR ;
WARACH, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (10) :708-716