MR-ANGIOGRAPHY OF NORMAL PELVIC ARTERIES - COMPARISON OF SIGNAL INTENSITY AND CONTRAST-TO-NOISE RATIO FOR 3 DIFFERENT INFLOW TECHNIQUES

被引:36
作者
YUCEL, EK [1 ]
SILVER, MS [1 ]
CARTER, AP [1 ]
机构
[1] PHILIPS MED SYST,SHELTON,CT 06484
关键词
D O I
10.2214/ajr.163.1.8010214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Two-dimensional (2D) time-of-flight (TOF) MR angiography has been the standard technique for evaluating arteries of the lower extremity. However, this technique is limited by artifacts resulting from vessel pulsation, as well as by relatively poor vessel-to-background contrast. The purpose of this study was to evaluate two cardiac-gated inflow techniques to determine whether they exhibited better contrast and signal performance than the standard technique of 2D TOF MR angiography of the iliac arteries. SUBJECTS AND METHODS. Fourteen subjects who had no clinical evidence of vascular disease had standard 20 TOF, gated 2D TOF, and gated 2D turbo field-echo MR angiography. Images were evaluated for signal-intensity ratio, signal-to-noise ratio, and contrast-to-noise ratio, in addition to qualitative evaluation. RESULTS. Turbo field-echo MR angiography exhibited significantly higher signal-intensity, signal-to-noise, and contrast-to-noise ratios than did either gated or standard MR angiography for all vessel segments. We found no significant difference between gated and standard 2D TOF techniques for any vessel segment. Qualitative features of turbo field-echo MR angiography included improved visualization of horizontal Vessel segments compared with the standard 2D TOF technique, less effective venous saturation compared with either the gated or standard 2D TOF technique, and increased ghosting artifacts compared with the gated 2D TOF technique. CONCLUSION. Two-dimensional turbo field-echo MR angiography exhibits improved signal and contrast for evaluation of normal iliac segments compared with standard or gated 2D TOF MR angiography. This technique should replace standard 2D TOF MR angiography for evaluation of the iliac arteries.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 23 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] THE POTENTIAL FOR LOWER-EXTREMITY REVASCULARIZATION WITHOUT CONTRAST ARTERIOGRAPHY - EXPERIENCE WITH MAGNETIC-RESONANCE ANGIOGRAPHY
    CAMBRIA, RP
    YUCEL, EK
    BREWSTER, DC
    LITALIEN, G
    GERTLER, JP
    LAMURAGLIA, GM
    KAUFMAN, JA
    WALTMAN, AC
    ABBOTT, WM
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 17 (06) : 1050 - 1057
  • [3] MR ANGIOGRAPHY WITH PULSATILE FLOW
    DEGRAAF, RG
    GROEN, JP
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (01) : 25 - 34
  • [4] FAST TIME-OF-FLIGHT MR-ANGIOGRAPHY WITH IMPROVED BACKGROUND SUPPRESSION
    EDELMAN, RR
    CHIEN, D
    ATKINSON, DJ
    SANDSTROM, J
    [J]. RADIOLOGY, 1991, 179 (03) : 867 - 870
  • [5] MR ANGIOGRAPHY OF VASCULAR GRAFTS IN CHILDREN
    FILLMORE, DJ
    YUCEL, EK
    BRIGGS, SE
    STEINBERG, FL
    WALTMAN, AC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) : 1069 - 1071
  • [6] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    FRAM, EK
    KELLER, PJ
    BIRD, CR
    HODAK, JA
    FLOM, RA
    [J]. RADIOLOGY, 1992, 182 (03) : 761 - 768
  • [7] CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US
    HUSTON, J
    LEWIS, BD
    WIEBERS, DO
    MEYER, FB
    RIEDERER, SJ
    WEAVER, AL
    [J]. RADIOLOGY, 1993, 186 (02) : 339 - 344
  • [8] MAGNETIC-RESONANCE-IMAGING - A RELIABLE TEST FOR THE EVALUATION OF PROXIMAL ATHEROSCLEROTIC RENAL ARTERIAL-STENOSIS
    KENT, KC
    EDELMAN, RR
    KIM, DS
    STEINMAN, TI
    PORTER, DH
    SKILLMAN, JJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1991, 13 (02) : 311 - 318
  • [9] LITT AW, 1991, AM J ROENTGENOL, V156, P611
  • [10] PREOPERATIVE AND POSTOPERATIVE IMAGING OF VASCULARIZED FIBULAR GRAFTS
    MANASTER, BJ
    COLEMAN, DA
    BELL, DA
    [J]. RADIOLOGY, 1990, 176 (01) : 161 - 166