We develop an automated method of characterizing the late atrial filling phase of diastole by fitting a kinematic model for diastolic filling to the clinical Doppler A-wave contour. The result is a set of model parameters which completely characterizes the contour. We have previously derived a parameterized diastolic filling (PDF) model, which predicts the time-dependent transmitral blood flow velocity obtained by Doppler echocardiography. An automated method to determine the PDF model parameters for early rapid filling from the clinical Doppler E-wave has also been developed and validated. The method consists of digitizing the acoustic Doppler waveform, recreating the Doppler velocity profile, extracting the maximum velocity envelope, and fitting the PDF model for early filling to the envelope. In the current work, we apply the same general approach for PDF parameter determination for the late atrial filling phase of diastole. To assess the presence and significance of near-degeneracies in the model parameter set, numerical experiments (consisting of fitting the model to a model-generated contour to which Gaussian noise was added) were performed. These revealed a two-dimensional degeneracy in four-dimensional parameter space which could be removed by using two kinematic simplifications: critical damping and resonant forcing. We show that these degeneracy-eliminating approximations do not limit the ability of the model to predict clinical A-wave contours.
引用
收藏
页码:859 / 869
页数:11
相关论文
共 15 条
  • [11] NUDELMAN SP, 1994, J AM SOC ECHOCARDI S, V23, pA192
  • [12] PRESS W, 1988, NUMERCIAL RECIPES C
  • [13] THE HEART AS A SUCTION PUMP
    ROBINSON, TF
    FACTOR, SM
    SONNENBLICK, EH
    [J]. SCIENTIFIC AMERICAN, 1986, 254 (06) : 84 - 91
  • [14] PHYSICAL AND PHYSIOLOGICAL DETERMINANTS OF TRANSMITRAL VELOCITY - NUMERICAL-ANALYSIS
    THOMAS, JD
    NEWELL, JB
    CHOONG, CYP
    WEYMAN, AE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 260 (05): : H1718 - H1730
  • [15] Wilkins GT, 1994, PRINCIPLES PRACTICE, V2nd, P1227