FLOW-INJECTION SYSTEMS FOR DIRECTLY COUPLING ONLINE DIGESTIONS WITH ANALYTICAL ATOMIC SPECTROMETRY .2. REACTIONS IN A MICROWAVE FIELD

被引:25
作者
GLUODENIS, TJ [1 ]
TYSON, JF [1 ]
机构
[1] UNIV MASSACHUSETTS,DEPT CHEM,AMHERST,MA 01003
关键词
FLOW INJECTION; SLURRY SAMPLING; ONLINE PRESSURE DIGESTION; MICROWAVE DIGESTION; STOPPED FLOW;
D O I
10.1039/ja9930800697
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection system incorporating a stopped-flow microwave-heated reactor was constructed for the preparation of solutions for subsequent analysis by atomic spectrometric techniques. Slurry samples were injected into the manifold and transported into a glass reactor mounted inside a microwave oven. Nitric acid was flushed into the reactor, which was then sealed and the contents were heated by an appropriate microwave programme so that the pressure was held at 400 lb in-2 for 5 min. During this period the presssure was continuously monitored. After cooling, the reactor was vented and the contents were flushed out into a calibrated flask and diluted to volume. The procedure was evaluated by the determination of some minor elements in cocoa powder (for which the results were compared with those of two other digestion procedures), Horse Kidney (International Atomic Energy Agency Certified Reference Material H-8) and coal [National Institute of Standards and Technology Standard Reference Material 1632b Trace Elements in Coal (Bituminous)]. A comparison of the results showed no significant difference (95% confidence) for the trace element contents of these materials between the flow injection method and other two methods of sample preparation. An analysis of variance showed no indication of sample slurry inhomogeneity. Low recoveries were obtained for the coal material, perhaps owing to incomplete dissolution of the silicate constituents.
引用
收藏
页码:697 / 704
页数:8
相关论文
共 20 条
[1]   COMPARISON OF A WET PRESSURE DIGESTION METHOD WITH OTHER COMMONLY USED WET AND DRY-ASHING METHODS [J].
ADRIAN, WJ .
ANALYST, 1973, 98 (1164) :213-216
[2]   CHEMICAL OXYGEN-DEMAND DETERMINATION IN WELL AND RIVER WATERS BY FLOW-INJECTION ANALYSIS USING A MICROWAVE-OVEN DURING THE OXIDATION STEP [J].
BALCONI, ML ;
BORGARELLO, M ;
FERRAROLI, R ;
REALINI, F .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :295-299
[3]   DETERMINATION OF ZINC AND CADMIUM IN SMALL AMOUNTS OF BIOLOGICAL TISSUES BY MICROWAVE-ASSISTED DIGESTION AND FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, M ;
BURGUERA, JL ;
ALARCON, OM .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :421-427
[4]   ONLINE MICROWAVE-OVEN DIGESTION FLAME ATOMIC-ABSORPTION ANALYSIS OF SOLID SAMPLES [J].
CARBONELL, V ;
DELAGUARDIA, M ;
SALVADOR, A ;
BURGUERA, JL ;
BURGUERA, M .
ANALYTICA CHIMICA ACTA, 1990, 238 (02) :417-421
[5]  
DELAGUARDIA M, 1988, J FLOW INJECTION ANA, V5, P121
[6]   FLOW-INJECTION SYSTEMS FOR DIRECTLY COUPLING ONLINE DIGESTIONS WITH ANALYTICAL ATOMIC SPECTROMETRY .1. DISSOLUTION OF COCOA UNDER STOPPED-FLOW, HIGH-PRESSURE CONDITIONS [J].
GLUODENIS, TJ ;
TYSON, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :301-306
[7]   25-YEARS OF ANALYTICAL ATOMIC SPECTROSCOPY [J].
GREENFIELD, S ;
HIEFTJE, GM ;
OMENETTO, N ;
SCHEELINE, A ;
SLAVIN, W .
ANALYTICA CHIMICA ACTA, 1986, 180 :69-98
[8]   ONLINE MICROWAVE DIGESTION OF SLURRY SAMPLES WITH DIRECT FLAME ATOMIC-ABSORPTION SPECTROMETRIC ELEMENTAL DETECTION [J].
HASWELL, SJ ;
BARCLAY, D .
ANALYST, 1992, 117 (02) :117-120
[9]   DETERMINATION OF TOTAL PHOSPHORUS IN WATERS WITH AMPEROMETRIC DETECTION BY COUPLING OF FLOW-INJECTION ANALYSIS WITH CONTINUOUS MICROWAVE-OVEN DIGESTION [J].
HINKAMP, S ;
SCHWEDT, G .
ANALYTICA CHIMICA ACTA, 1990, 236 (02) :345-350
[10]  
ISSAC RA, 1975, J AOAC, V58, P436