DETERMINATION OF AN ENDOTHELIN RECEPTOR ANTAGONIST IN HUMAN PLASMA BY NARROW-BORE LIQUID-CHROMATOGRAPHY AND IONSPRAY TANDEM MASS-SPECTROMETRY

被引:17
作者
LAUSECKER, B [1 ]
HOPFGARTNER, G [1 ]
机构
[1] F HOFFMANN LA ROCHE & CO LTD,DEPT DRUG METAB & KINET,BIOANALYT SECT,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1016/0021-9673(95)00331-G
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for the determination of a new endothelin receptor antagonist, Bosentan Ro 47-0203, in human plasma using narrow-bore liquid chromatography and ionspray tandem mass spectrometry. After protein precipitation with acetonitrile, the compounds were extracted with dichloromethane at pH 11. The compounds were chromatographed on a 2 mm I.D. reversed-phase column and introduced into the mass spectrometer with an ionspray (pneumatically assisted electrospray) interface at a Sow-rate of 170 mu l/min without postcolumn splitting. Two different internal standards were used for the assay: either a structural analogue or a deuterated analogue. The limit of quantification was 0.5.ng/ml using a 0.5-ml aliquot of plasma. Concentrations of the drug were determined in the range 0.5-200 ng/ml. The recovery from human plasma was 87%. The new API IIIplus collision cell was about five times more sensitive than the original API III cell. The assay was demonstrated to be sensitive, selective and robust for the analysis of over 1500 samples.
引用
收藏
页码:75 / 83
页数:9
相关论文
共 14 条
[1]   CONTRACTILE ACTIVITY OF 3 ENDOTHELINS (ET-1, ET-2 AND ET-3) ON THE HUMAN ISOLATED BRONCHUS [J].
ADVENIER, C ;
SARRIA, B ;
NALINE, E ;
PUYBASSET, L ;
LAGENTE, V .
BRITISH JOURNAL OF PHARMACOLOGY, 1990, 100 (01) :168-172
[2]   COMBINED LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY .3. APPLICATIONS OF THERMOSPRAY [J].
ARPINO, P .
MASS SPECTROMETRY REVIEWS, 1992, 11 (01) :3-40
[3]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[4]  
CLOZEL M, 1994, J PHARMACOL EXP THER, V270, P118
[5]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[6]  
EGGERS H, COMMUNICATIONS
[7]   HIGH-FLOW ION SPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HOPFGARTNER, G ;
WACHS, T ;
BEAN, K ;
HENION, J .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :439-446
[8]   ION-SPRAY MASS-SPECTROMETRIC DETECTION FOR LIQUID-CHROMATOGRAPHY - A CONCENTRATION-FLOW-SENSITIVE OR A MASS-FLOW-SENSITIVE DEVICE [J].
HOPFGARTNER, G ;
BEAN, K ;
HENION, J ;
HENRY, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 647 (01) :51-61
[9]   MICRO-LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY WITH DIRECT LIQUID INTRODUCTION [J].
LEE, ED ;
HENION, JD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (06) :253-264
[10]   ELECTROSPRAY AND TAYLOR-CONE THEORY, DOLES BEAM OF MACROMOLECULES AT LAST [J].
WILM, MS ;
MANN, M .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1994, 136 (2-3) :167-180