THE EFFECT OF ARTIFICIAL TEARS ON COMPUTER-ASSISTED CORNEAL TOPOGRAPHY IN NORMAL EYES AND AFTER PENETRATING KERATOPLASTY

被引:28
作者
PAVLOPOULOS, GP [1 ]
HORN, J [1 ]
FELDMAN, ST [1 ]
机构
[1] UNIV CALIF SAN DIEGO,SCH MED,DEPT OPHTHALMOL,LA JOLLA,CA 92093
关键词
D O I
10.1016/S0002-9394(14)72775-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To examine the effect of adding artificial tears for one minute to normal eyes and eyes that have undergone keratoplasty by using computer-assisted videokeratography. METHODS: We prospectively analyzed 24 nor mal corneas (24 patients) chosen by random number table (reproducibility section [10 eyes], tear section [14 eyes]) as well as 14 postkeratoplasty corneas. The parametric descriptors analyzed statistically included the simulated keratometry value, surface asymmetry index, surface regularity index, power at the vertex normal, and the pupil offsets from the visual axis. Vectoral analysis was used to calculate the difference in power and axis between the simulated keratometry values before and after tear instillation. RESULTS: In normal eyes, tear instillation in creased the surface asymmetry index (0.28 +/- 0.34, P = .01), changed the simulated keratometry value (0.23 diopter by 27.8 degrees), and power (0.79 +/- 0.82 diopters, P = .004) and location (0.91 +/- 0.76 mm) of the steepest point of the cornea changed. In postkeratoplasty eyes, the surface regularity index decreased (0.49 +/- 0.80, P = .04), surface asymmetry index decreased (0.37 +/- 1.03, P = .21), mean simulated keratometry value changed (1.04 diopters by 1.01 degrees), and power (0.70 +/- 2.34 diopters, P = .28) and location (1.04 +/- 1.17 mm) of the steepest point of the cornea changed. Changes were greater than the variability of the surface regularity index (0.07 +/- 0.05), surface asymmetry index (0.04 +/- 0.03), simulated keratometry value power (0.08 +/- 0.06 diopter), and axis (4.6 +/- 15 degrees). CONCLUSIONS: The addition of artificial tears to normal or regular and symmetric eyes that have undergone keratoplasty worsened symmetry and changed the power and location of the steepest point. However, the addition of artificial tears to irregular eyes that have undergone penetrating keratoplasty created a more regular and symmetric surface and significantly altered the simulated keratometry values. We recommend that corneal topography be performed before the application of artificial tears.
引用
收藏
页码:712 / 722
页数:11
相关论文
共 20 条
[1]   CLASSIFICATION OF NORMAL CORNEAL TOPOGRAPHY BASED ON COMPUTER-ASSISTED VIDEOKERATOGRAPHY [J].
BOGAN, SJ ;
WARING, GO ;
IBRAHIM, O ;
DREWS, C ;
CURTIS, L .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :945-949
[2]  
BRONSHTEIN IN, 1985, HDB MATH, P173
[3]  
Dingeldein S A, 1989, Refract Corneal Surg, V5, P372
[4]   THE TOPOGRAPHY OF NORMAL CORNEAS [J].
DINGELDEIN, SA ;
KLYCE, SD .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (04) :512-518
[5]  
GORMLEY DJ, 1988, CORNEA, V7, P30
[6]   REPRODUCIBILITY OF NORMAL CORNEAL POWER MEASUREMENTS WITH A KERATOMETER, PHOTOKERATOSCOPE, AND VIDEO IMAGING-SYSTEM [J].
HANNUSH, SB ;
CRAWFORD, SL ;
WARING, GO ;
GEMMILL, MC ;
LYNN, MJ ;
NIZAM, A .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (04) :539-544
[7]  
Jaffe NS., 1975, T AM ACAD OPHTHALMOL, V79, P615
[8]  
Klyce S D, 1989, Refract Corneal Surg, V5, P368
[9]  
Lin D T, 1990, Refract Corneal Surg, V6, P21
[10]  
LIN DTC, 1990, OPHTHALMOLOGY, V97, P934