ONLINE QUANTIFICATION OF VENTRICULAR-FUNCTION DURING DOBUTAMINE STRESS ECHOCARDIOGRAPHY

被引:48
作者
PEREZ, JE
WAGGONER, AD
DAVILAROMAN, VG
CARDONA, H
MILLER, JG
机构
[1] WASHINGTON UNIV, SCH MED, DIV CARDIOVASC, 660 S EUCLID, BOX 8086, ST LOUIS, MO 63110 USA
[2] WASHINGTON UNIV, SCH MED, DEPT PHYS, ST LOUIS, MO 63110 USA
关键词
ECHOCARDIOGRAPHY; AUTOMATIC EDGE DETECTION; DOBUTAMINE STRESS ECHOCARDIOGRAPHY;
D O I
10.1093/oxfordjournals.eurheartj.a060123
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To develop an approach for on-line quantification of left ventricular size and function during pharmacological stress testing we employed echocardiographic automatic edge detection via integrated backscatter imaging during dobutamine infusion in 27 patients. Ventricular cavity areas, fractional area change and rate of cavity area change were obtained on-line with instantaneous graphic display of the data. When compared to baseline image data, patients with a normal response exhibited modest (15%) reduction in end-diastolic cavity areas at peak dobutamine level, but marked (33%) reduction in systolic areas yielding a 52% increase in fractional area change (n = 13; P<0·001). The second group of patients (n = 14) had an abnormal response characterized by limited changes in measured parameters of ventricular function and reduced fractional area change (P< 0·05). On-line quantification during pharmacological stress echocardiography is a promising addition to the test for surveillance and objective instantaneous evaluation of global cardiac responses. © 1992 The European Society of Cardiology.
引用
收藏
页码:1669 / 1676
页数:8
相关论文
共 31 条
[21]  
Schiller N B, 1989, J Am Soc Echocardiogr, V2, P358
[22]  
SKORTON DJ, 1990, CARDIAC IMAGING PRIN, P538
[23]   DRUG-THERAPY - DOBUTAMINE - NEW SYNTHETIC CARDIOACTIVE SYMPATHETIC AMINE [J].
SONNENBLICK, EH ;
FRISHMAN, WH ;
LEJEMTEL, TH .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (01) :17-22
[24]   DOPPLER MITRAL PRESSURE HALF-TIME - A CLINICAL TOOL IN SEARCH OF THEORETICAL JUSTIFICATION [J].
THOMAS, JD ;
WEYMAN, AE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :923-929
[25]   A REAL-TIME INTEGRATED BACKSCATTER MEASUREMENT SYSTEM FOR QUANTITATIVE CARDIAC TISSUE CHARACTERIZATION [J].
THOMAS, LJ ;
WICKLINE, SA ;
PEREZ, JE ;
SOBEL, BE ;
MILLER, JG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) :27-32
[26]   STUDY OF LEFT-VENTRICULAR FUNCTION FROM DIGITIZED ECHOCARDIOGRAMS [J].
UPTON, MT ;
GIBSON, DG .
PROGRESS IN CARDIOVASCULAR DISEASES, 1978, 20 (05) :359-384
[27]  
Vandenberg B F, 1989, J Am Soc Echocardiogr, V2, P308
[28]  
VANDENBERG B F, 1991, Journal of the American College of Cardiology, V17, p291A
[29]   QUANTITATIVE ULTRASONIC TISSUE CHARACTERIZATION WITH REAL-TIME INTEGRATED BACKSCATTER IMAGING IN NORMAL HUMAN-SUBJECTS AND IN PATIENTS WITH DILATED CARDIOMYOPATHY [J].
VERED, Z ;
BARZILAI, B ;
MOHR, GA ;
THOMAS, LJ ;
GENTON, R ;
SOBEL, BE ;
SHOUP, TA ;
MELTON, HE ;
MILLER, JG ;
PEREZ, JE .
CIRCULATION, 1987, 76 (05) :1067-1073
[30]  
WAGGONER AD, 1991, J AM SOC ECHO, V4, P304