COMPUTER-SIMULATIONS OF THE RESPONSES OF PASSIVE AND ACTIVE INTEGRATED MICROBIOSENSORS TO CELL-ACTIVITY

被引:10
作者
GRATTAROLA, M
MARTINOIA, S
MASSOBRIO, G
CAMBIASO, A
ROSICHINI, R
TETTI, M
机构
[1] Biophysical and Electronic Engineering Department, University of Genoa, Genoa
关键词
D O I
10.1016/0925-4005(91)80120-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection of cell activity via solid-state microtransducers is a rapidly growing research area. In order to design and test microdevices optimized for specific biological applications, ranging from cell electrophysiology to cell pharmacology, there is an increasing need for systematic computer simulations. As specific examples, the performances of noble-metal microelectrodes, ion-sensitive field-effect transistors (ISFETs) and light-addressable potentiometric sensors (LAPs) are analysed and discussed by means of computer simulations based on their equivalent circuits.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 13 条
  • [1] ISFETS USING INORGANIC GATE THIN-FILMS
    ABE, H
    ESASHI, M
    MATSUO, T
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1979, 26 (12) : 1939 - 1944
  • [2] EXTRACELLULAR POTENTIAL RECORDINGS BY MEANS OF A FIELD-EFFECT TRANSISTOR WITHOUT GATE METAL, CALLED OSFET
    BERGVELD, P
    WIERSMA, J
    MEERTENS, H
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (02) : 136 - 144
  • [3] DETECTION OF CELL-ACTIVITY VIA ISFET DEVICES - MODELING AND COMPUTER-SIMULATIONS
    CAMBIASO, A
    GRATTAROLA, M
    ARNALDI, G
    MARTINOIA, S
    MASSOBRIO, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 373 - 379
  • [4] AN EXTRACELLULAR MICROELECTRODE ARRAY FOR MONITORING ELECTROGENIC CELLS IN CULTURE
    CONNOLLY, P
    CLARK, P
    CURTIS, ASG
    DOW, JAT
    WILKINSON, CDW
    [J]. BIOSENSORS & BIOELECTRONICS, 1990, 5 (03) : 223 - 234
  • [5] GRATTAROLA M, IN PRESS CYTOTECHNOL
  • [6] LIGHT-ADDRESSABLE POTENTIOMETRIC SENSOR FOR BIOCHEMICAL SYSTEMS
    HAFEMAN, DG
    PARCE, JW
    MCCONNELL, HM
    [J]. SCIENCE, 1988, 240 (4856) : 1182 - 1185
  • [7] ACTIVE MICROELECTRODE ARRAY TO RECORD FROM THE MAMMALIAN CENTRAL NERVOUS-SYSTEM INVITRO
    JOBLING, DT
    SMITH, JG
    WHEAL, HV
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) : 553 - 560
  • [8] ISFET-BASED BIOSENSOR MODELING WITH SPICE
    MASSOBRIO, G
    GRATTAROLA, M
    MATTIOLI, G
    MATTIOLI, F
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 401 - 407
  • [9] DETECTION OF CELL-AFFECTING AGENTS WITH A SILICON BIOSENSOR
    PARCE, JW
    OWICKI, JC
    KERCSO, KM
    SIGAL, GB
    WADA, HG
    MUIR, VC
    BOUSSE, LJ
    ROSS, KL
    SIKIC, BI
    MCCONNELL, HM
    [J]. SCIENCE, 1989, 246 (4927) : 243 - 247
  • [10] A LONG-TERM INVITRO SILICON-BASED MICROELECTRODE-NEURON CONNECTION
    REGEHR, WG
    PINE, J
    RUTLEDGE, DB
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (12) : 1023 - 1032