DETERMINATION OF TRACE ALUMINUM BY DIFFERENTIAL PULSE ADSORPTIVE STRIPPING VOLTAMMETRY OF ALUMINUM(III)-8-HYDROXYQUINOLINE COMPLEX

被引:40
作者
CAI, QT [1 ]
KHOO, SB [1 ]
机构
[1] NATL UNIV SINGAPORE,DEPT CHEM,KENT RIDGE,SINGAPORE 0511,SINGAPORE
关键词
STRIPPING VOLTAMMETRY; ALUMINUM; WATERS;
D O I
10.1016/0003-2670(93)85043-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive differential-pulse adsorptive stripping voltammetric method, based on the formation of an electroactive complex between aluminium(III) and 8-hydroxyquinoline (HOx), is presented for the determination of trace levels of aluminium. The complex showed an oxidative peak potential at + 0.876 V vs. Ag/AgCl (saturated KCl) at a glassy carbon (GC) electrode in aqueous ammonium acetate (0.024 M, pH 6.8). A good linear relationship between the peak current and Al(III) concentration in the ranges 4.00 x 10(-8)-5.00 x 10(-6) and 8.00 X 10(-6)-4.00 x 10(-5) M were observed. In the lower Al(III) concentration region, the anodic peak was the result of the stripping of the adsorbed Al(III)-HOx complex, whereas in the higher concentration range, the diffusional oxidation current of the solution species predominated. A surface saturation region was observed from 5.00 x 10(-6) to 8.00 x 10(-6) M Al(III). Relatively few interferences were found and these were easily masked. The detection limit for Al(III) for this method is 1.00 x 10(-8) M and ten determinations of Al(III) at 1.00 x 10(-7) M gave a relative standard deviation of 6.2%. The method was employed in the analysis of Al(III) in a US Environmental Protection Agency water pollution quality control sample (WP 386) and excellent agreement with the certified value was obtained.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 20 条
  • [1] ADAMS RN, 1969, ELECTROCHEMISTRY SOL, P363
  • [2] Baes C. F., 1976, HYDROLYSIS CATIONS, P122
  • [3] EXTRACTION SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF ALUMINUM IN SILICATES
    BANERJEE, NL
    SINHA, BC
    [J]. TALANTA, 1990, 37 (10) : 1017 - 1020
  • [4] EVALUATION OF THE LVOV PLATFORM AND MATRIX MODIFICATION FOR THE DETERMINATION OF ALUMINUM IN SERUM
    BETTINELLI, M
    BARONI, U
    FONTANA, F
    POISETTI, P
    [J]. ANALYST, 1985, 110 (01) : 19 - 22
  • [5] CHENG KL, 1982, CRC HDB ORGANIC ANAL, P253
  • [6] VOLTAMMETRIC DETERMINATION OF ALUMINUM(III) USING A CHEMICALLY MODIFIED ELECTRODE
    DOWNARD, AJ
    POWELL, HKJ
    XU, SH
    [J]. ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) : 157 - 163
  • [7] FLOW-INJECTION ANALYSIS FOR ALUMINUM WITH INDIRECT AMPEROMETRIC DETECTION
    DOWNARD, AJ
    POWELL, HKJ
    XU, SH
    [J]. ANALYTICA CHIMICA ACTA, 1992, 256 (01) : 117 - 123
  • [8] ONLINE ALUMINUM PRECONCENTRATION ON CHELATING RESIN AND ITS FIA SPECTROFLUOROMETRIC DETERMINATION IN FOODS AND DIALYSIS CONCENTRATES
    FERNANDEZ, P
    CONDE, CP
    GUTIERREZ, A
    CAMARA, C
    [J]. TALANTA, 1991, 38 (12) : 1387 - 1392
  • [9] Hammerich O., 1983, ORGANIC ELECTROCHEMI, P485
  • [10] TRACE-METAL ENRICHMENT BY AUTOMATED ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY
    HIRATA, S
    HONDA, K
    KUMAMARU, T
    [J]. ANALYTICA CHIMICA ACTA, 1989, 221 (01) : 65 - 76