ELECTRODE SURFACE-AREA IS AN IMPORTANT VARIABLE FOR DEFIBRILLATION

被引:16
作者
SINGER, I
GOLDSMITH, J
MALDONADO, C
机构
[1] University of Louisville, Louisville, Kentucky
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 01期
关键词
DEFIBRILLATION; SURFACE AREA; ENDOCARDIAL LEADS;
D O I
10.1111/j.1540-8159.1995.tb02511.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies have established efficacy of transseptal defibrillation. The purpose of the present study was to evaluate the role of transvenous electrode surface area for defibrillation. Sixteen dogs were randomized to 8 French and 5 French EnGuard(TM) electrodes; 8 dogs in each group. The length of the defibrillation coils was identical for both, but the surface area was different due to differences in the electrode diameters. Defibrillation threshold (DFT) testing was performed using a biphasic shock waveform, 6 msec(+)/2msec(-). Logistic regression analysis was used to determine if the probability of defibrillation adjusted for voltage, current, and energy wets different for 8 French electrodes. Logistic regression analysis found significant differences between 8 French and 5 French electrodes, with less voltage (P < 0.005), current (P < 0.03), and energy (P < 0.001) required at any level of probability to defibrillate for 8 French electrodes. These results support the conclusion that the surface area for endocardial electrodes is a significant factor for defibrillation. Therefore, when designing endocardial electrodes a desirable objective of reducing the electrode size should be weighed against the need to minimize DFTs.
引用
收藏
页码:233 / 236
页数:4
相关论文
共 9 条
[1]   ELECTRODE SYSTEM INFLUENCE ON BIPHASIC WAVE-FORM DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
TROUTMAN, C ;
JOHNSON, G ;
MEHRA, R ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
GARTMAN, DM .
CIRCULATION, 1991, 84 (02) :665-671
[2]   COMPARISON OF THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VENTRICULAR VULNERABILITY [J].
CHEN, PS ;
SHIBATA, N ;
DIXON, EG ;
MARTIN, RO ;
IDEKER, RE .
CIRCULATION, 1986, 73 (05) :1022-1028
[3]   RESPONSE OF CULTURED MYOCARDIAL-CELLS TO COUNTERSHOCK-TYPE ELECTRIC-FIELD STIMULATION [J].
JONES, JL ;
LEPESCHKIN, E ;
JONES, RE ;
RUSH, S .
AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 235 (02) :H214-H222
[4]   DEFIBRILLATION THRESHOLD - CLINICAL UTILITY AND THERAPEUTIC IMPLICATIONS [J].
SINGER, I ;
LANG, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (06) :932-949
[5]   DEFIBRILLATION EFFICACY USING 2 LOW-PROFILE ENDOCARDIAL ELECTRODES [J].
SINGER, I ;
MALDONADO, C ;
VANCE, F ;
SIMPSON, P ;
KUPERSMITH, J .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1991, 302 (02) :82-88
[6]  
SINGER I, 1994, PACE 2, V17, P816
[7]   THE IMPLANTED DEFIBRILLATOR - RELATION OF DEFIBRILLATING LEAD CONFIGURATION AND CLINICAL-VARIABLES TO DEFIBRILLATION THRESHOLD [J].
TROUP, PJ ;
CHAPMAN, PD ;
OLINGER, GN ;
KLEINMAN, LH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (06) :1315-1321
[9]   TERMINATION OF VENTRICULAR-FIBRILLATION IN DOGS BY DEPOLARIZING A CRITICAL AMOUNT OF MYOCARDIUM [J].
ZIPES, DP ;
FISCHER, J ;
KING, RM ;
NICOLL, AD ;
JOLLY, WW .
AMERICAN JOURNAL OF CARDIOLOGY, 1975, 36 (01) :37-44