DETERMINATION OF CARBON-MONOXIDE AND CARBON-DIOXIDE CONCENTRATIONS AT TEMPERATURES BETWEEN 295-K AND 1250-K USING FOURIER-TRANSFORM INFRARED-ABSORPTION SPECTROSCOPY

被引:6
作者
MEDVECZ, PJ [1 ]
NICHOLS, KM [1 ]
机构
[1] INST PAPER SCI & TECHNOL,ATLANTA,GA 30318
关键词
INFRARED; FT-IR; CO; CO2; ABSORPTION SPECTRA; CONCENTRATION ANALYSIS; COMBUSTION GASES;
D O I
10.1366/0003702924123575
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fourier transform infrared absorption spectroscopy has been used for the determination of CO and CO2 gas concentrations in a high-temperature cell. The gas mixtures analyzed consisted of CO, CO2, and nitrogen; among the samples, the concentration of CO was varied between 0.5 and 4.7% and the CO2 ranged between 0.7 and 4.9%. The temperature of the gas cell was varied between 295 and 1250 K, while the pressure was maintained at atmospheric. Throughout this temperature range, 123 absorption spectra were recorded in the gas cell at a nominal instrument resolution of 0.25 cm-1. The absorption lines used for the concentration analysis consisted of 22 P-branch CO vibrational-rotational lines from the fundamental absorption band, and 19 R-branch CO2 vibrational-rotational lines from the nu3 fundamental absorption band. All of the peak heights used for the concentration calculations were first numerically corrected for photometric errors resulting from the finite resolution of the FT-IR instrument. The corrected peak heights were assumed to follow the Bouguer-Lambert law at a constant furnace temperature. Fifty-one of the spectra were used to determine the temperature dependence of the line strength for each of the 41 lines. The experimentally obtained line strengths were then used to determine the gas concentrations of all 123 spectra. The calculated concentrations were compared to NDIR instrument measurements of the gas composition exiting the flow-through high-temperature gas cell. Comparison of the NDIR measured gas concentrations with the calculated concentrations from absorption spectra yielded an average accuracy of 3.6% for the CO spectra and 4.9% for the CO2 spectra.
引用
收藏
页码:1887 / 1894
页数:8
相关论文
共 15 条
[1]   ERRORS IN ABSORBANCE MEASUREMENTS IN INFRARED FOURIER-TRANSFORM SPECTROMETRY BECAUSE OF LIMITED INSTRUMENT RESOLUTION [J].
ANDERSON, RJ ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2339-2347
[2]   DETERMINATION OF ROTATIONAL TEMPERATURES OF DIATOMIC-MOLECULES FROM ABSORPTION-SPECTRA MEASURED AT MODERATE RESOLUTION [J].
ANDERSON, RJ ;
GRIFFITHS, PR .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1977, 17 (03) :393-401
[3]  
GROSS LA, 1985, INFRARED METHODS GAS, pCH3
[4]  
HANSON RK, 1983, P SOC PHOTO-OPT INST, V438, P75
[5]   ACCURATE CALCULATED TABULATIONS OF CO LINE BROADENING BY H2O, N2, O2, AND CO2 IN THE 200-3000-K TEMPERATURE-RANGE [J].
HARTMANN, JM ;
ROSENMANN, L ;
PERRIN, MY ;
TAINE, J .
APPLIED OPTICS, 1988, 27 (15) :3063-3065
[6]   LINE PARAMETER MEASUREMENTS AND CALCULATIONS OF CO BROADENED BY H2O AND CO2 AT ELEVATED-TEMPERATURES [J].
LOWRY, HS ;
FISHER, CJ .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1984, 31 (06) :575-581
[7]   DETERMINATION OF GAS TEMPERATURES AT 295-K-1273-K USING CO VIBRATIONAL-ROTATIONAL ABSORPTION-SPECTRA RECORDED WITH AN FT-IR SPECTROMETER [J].
MEDVECZ, PJ ;
NICHOLS, KM ;
CLAY, DT ;
ATALLA, R .
APPLIED SPECTROSCOPY, 1991, 45 (08) :1350-1359
[8]  
MEDVECZ PJ, 1991, THESIS I PAPER SCI T
[9]   MEASUREMENTS OF INTENSITIES AND SELF-GAS AND FOREIGN-GAS-BROADENED HALF-WIDTHS OF SPECTRAL-LINES IN THE CO FUNDAMENTAL-BAND [J].
NAKAZAWA, T ;
TANAKA, M .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1982, 28 (05) :409-416
[10]  
OTTESEN DK, 1985, P INT C COAL SCI, P351