XENON-ENHANCED COMPUTED-TOMOGRAPHY COMPARED WITH [C-14] IODOANTIPYRINE FOR NORMAL AND LOW CEREBRAL BLOOD-FLOW STATES IN BABOONS

被引:29
作者
WOLFSON, SK
CLARK, J
GREENBERG, JH
GUR, D
YONAS, H
BRENNER, RP
COOK, EE
LORDEON, PA
机构
[1] UNIV PITTSBURGH,DEPT NEUROL SURG,PITTSBURGH,PA 15260
[2] UNIV PENN,CEREBROVASC RES CTR,PHILADELPHIA,PA 19104
[3] UNIV PITTSBURGH,DEPT DIAGNOST RADIOL,PITTSBURGH,PA 15260
[4] UNIV PITTSBURGH,DEPT RADIAT HLTH,PITTSBURGH,PA 15260
[5] UNIV PITTSBURGH,DEPT PSYCHIAT & NEUROL,PITTSBURGH,PA 15260
[6] WESTERN PSYCHIAT INST & CLIN,EEG LAB,PITTSBURGH,PA 15261
关键词
Baboons; Cerebral blood flow; Tomography; emission computed; Xenon;
D O I
10.1161/01.STR.21.5.751
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The correlation between the acute, invasive diffusible [14C]iodoantipyrine technique for cerebral blood flow and the noninvasive xenon-enhanced computed tomographic method has been assessed by simultaneous measurements in the baboon. Blood flows in small tissue volumes (about 0.125 cm3) were directly compared in normal and low flow states. These studies demonstrate a statistically significant association between the two methods (p<0.001). Similar correlations were obtained by both the Kendall (r) and the Spearman (r) methods (r=0.67 to 0.92, n ≥ l9 for each study). The problems and limitations of such correlations are discussed. © 1990 American Heart Association, Inc.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 34 条
[1]   MEASUREMENT OF LOCAL BLOOD FLOW WITH HYDROGEN GAS [J].
AUKLAND, K ;
BERLINER, RW ;
BOWER, BF .
CIRCULATION RESEARCH, 1964, 14 (02) :164-&
[2]   XENON ENHANCED CT FOR ANALYSIS OF CEREBRAL INTEGRITY, PERFUSION, AND BLOOD-FLOW [J].
DRAYER, BP ;
WOLFSON, SK ;
REINMUTH, OM ;
DUJOVNY, M ;
BOEHNKE, M ;
COOK, EE .
STROKE, 1978, 9 (02) :123-130
[3]   COMPARISON BETWEEN THE XE-133 CLEARANCE METHOD AND THE MICROSPHERE TECHNIQUE IN CEREBRAL BLOOD-FLOW DETERMINATIONS IN THE DOG [J].
FAN, FC ;
CHEN, RYZ ;
SCHUESSLER, GB ;
CHIEN, S .
CIRCULATION RESEARCH, 1979, 44 (05) :653-659
[4]  
GIBBS J, 1983, J CEREB BLOOD FLO S1, V3, pS590
[5]   ERRORS ASSOCIATED WITH SINGLE-SCAN DETERMINATIONS OF REGIONAL CEREBRAL BLOOD-FLOW BY XENON ENHANCED-CT [J].
GOOD, WF ;
GUR, D ;
SHABASON, L ;
WOLFSON, SK ;
YONAS, H ;
LATCHAW, RE ;
HERBERT, DL ;
KENNEDY, WH .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (04) :531-537
[6]   XENON ENHANCED DYNAMIC COMPUTED-TOMOGRAPHY - MULTILEVEL CEREBRAL BLOOD-FLOW STUDIES [J].
GUR, D ;
YONAS, H ;
HERBERT, D ;
WOLFSON, SK ;
KENNEDY, WH ;
DRAYER, BP ;
GRAY, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :334-340
[7]   PROGRESS IN CEREBROVASCULAR-DISEASE - LOCAL CEREBRAL BLOOD-FLOW BY XENON ENHANCED CT [J].
GUR, D ;
WOLFSON, SK ;
YONAS, H ;
GOOD, WF ;
SHABASON, L ;
LATCHAW, RE ;
MILLER, DM ;
COOK, EE .
STROKE, 1982, 13 (06) :750-758
[8]   INVIVO MAPPING OF LOCAL CEREBRAL BLOOD-FLOW BY XENON-ENHANCED COMPUTED-TOMOGRAPHY [J].
GUR, D ;
GOOD, WF ;
WOLFSON, SK ;
YONAS, H ;
SHABASON, L .
SCIENCE, 1982, 215 (4537) :1267-1268
[9]   MEASUREMENT OF CEREBRAL BLOOD-FLOW DURING XENON INHALATION AS MEASURED BY THE MICROSPHERES METHOD [J].
GUR, D ;
YONAS, H ;
JACKSON, DL ;
WOLFSON, SK ;
ROCKETTE, H ;
GOOD, WF ;
MAITZ, GS ;
COOK, EE ;
ARENA, VC .
STROKE, 1985, 16 (05) :871-874
[10]   SIMULTANEOUS MEASUREMENTS OF CEREBRAL BLOOD-FLOW BY THE XENON CT METHOD AND THE MICROSPHERE METHOD - A COMPARISON [J].
GUR, D ;
YONAS, H ;
JACKSON, DL ;
WOLFSON, SK ;
ROCKETTE, H ;
GOOD, WF ;
COOK, EE ;
ARENA, VC ;
WILLY, JA ;
MAITZ, GS .
INVESTIGATIVE RADIOLOGY, 1985, 20 (07) :672-677