XENON-ENHANCED COMPUTED-TOMOGRAPHY COMPARED WITH [C-14] IODOANTIPYRINE FOR NORMAL AND LOW CEREBRAL BLOOD-FLOW STATES IN BABOONS

被引:29
作者
WOLFSON, SK
CLARK, J
GREENBERG, JH
GUR, D
YONAS, H
BRENNER, RP
COOK, EE
LORDEON, PA
机构
[1] UNIV PITTSBURGH,DEPT NEUROL SURG,PITTSBURGH,PA 15260
[2] UNIV PENN,CEREBROVASC RES CTR,PHILADELPHIA,PA 19104
[3] UNIV PITTSBURGH,DEPT DIAGNOST RADIOL,PITTSBURGH,PA 15260
[4] UNIV PITTSBURGH,DEPT RADIAT HLTH,PITTSBURGH,PA 15260
[5] UNIV PITTSBURGH,DEPT PSYCHIAT & NEUROL,PITTSBURGH,PA 15260
[6] WESTERN PSYCHIAT INST & CLIN,EEG LAB,PITTSBURGH,PA 15261
关键词
Baboons; Cerebral blood flow; Tomography; emission computed; Xenon;
D O I
10.1161/01.STR.21.5.751
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The correlation between the acute, invasive diffusible [14C]iodoantipyrine technique for cerebral blood flow and the noninvasive xenon-enhanced computed tomographic method has been assessed by simultaneous measurements in the baboon. Blood flows in small tissue volumes (about 0.125 cm3) were directly compared in normal and low flow states. These studies demonstrate a statistically significant association between the two methods (p<0.001). Similar correlations were obtained by both the Kendall (r) and the Spearman (r) methods (r=0.67 to 0.92, n ≥ l9 for each study). The problems and limitations of such correlations are discussed. © 1990 American Heart Association, Inc.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 34 条
[21]  
MALLETT BL, 1965, CLIN SCI, V29, P179
[22]   LOCAL CEREBRAL BLOOD-FLOW MEASURED BY CT AFTER STABLE XENON INHALATION [J].
MEYER, JS ;
HAYMAN, LA ;
YAMAMOTO, M ;
SAKAI, F ;
NAKAJIMA, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (02) :239-251
[23]  
MEYER M, 1969, CEREBRAL BLOOD FLOW, P50
[24]   REGIONAL CEREBRAL BLOOD-FLOW ESTIMATED BY XENON-133 INHALATION [J].
OBRIST, WD ;
THOMPSON, HK ;
WANG, HS ;
WILKINSON, WE .
STROKE, 1975, 6 (03) :245-256
[25]   AN EVALUATION OF ERRORS IN THE DETERMINATION OF BLOOD-FLOW BY THE INDICATOR FRACTIONATION AND TISSUE EQUILIBRATION (KETY) METHODS [J].
PATLAK, CS ;
BLASBERG, RG ;
FENSTERMACHER, JD .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :47-60
[26]   Newer Techniques of Cerebral Blood Flow Measurement [J].
Posner, Jerome B. .
STROKE, 1972, 3 (03) :227-237
[27]   MEASUREMENT OF REGIONAL CEREBRAL BLOOD FLOW WITH ANTIPYRINE-14C IN AWAKE CATS [J].
REIVICH, M ;
JEHLE, J ;
SKOLOFF, L ;
KETY, SS .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (02) :296-&
[28]  
RUDOLPH AM, 1972, ACTA ENDOCRINOL-COP, V72, P112
[29]   MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW WITH ANTIPYRINE-IODO-C-14 [J].
SAKURADA, O ;
KENNEDY, C ;
JEHLE, J ;
BROWN, JD ;
CARBIN, GL ;
SOKOLOFF, L .
AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 234 (01) :H59-H66
[30]   EFFECT OF LOW CONCENTRATION STABLE XENON ON THE EEG POWER SPECTRUM [J].
SCLABASSI, RJ ;
LOFINK, RM ;
GUTHKELCH, AN ;
GUR, D ;
YONAS, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1987, 67 (04) :340-347