DETERMINATION OF N-NITROSODIMETHYLAMINE AT PART-PER-TRILLION LEVELS IN DRINKING WATERS AND CONTAMINATED GROUNDWATERS

被引:40
作者
TOMKINS, BA
GRIEST, WH
HIGGINS, CE
机构
[1] Organic Chemistry Section, Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Tennessee, P.O. Box 2008, Oak Ridge
关键词
D O I
10.1021/ac00119a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The carcinogen N-nitrosodimethylamine (NDMA) may be quantitated routinely at ultratrace (ng/L) levels in drinking water or contaminated groundwater, The aqueous sample is passed through a preconditioned Empore C-18 filter disk to remove neutral nonpolar species and then extracted continuously overnight with highest purity dichloromethane. The latter is then concentrated to 1 mL, and a large aliquot (up to 200 mu L) is loaded onto a dual-stage carbon sorbent trap, after which the solvent is removed with ultrapure helium, The concentrated residues are then injected orate a gas chromatographic column using a short-path thermal desorber. NDMA is selectively detected using a chemiluminescent nitrogen detector (CLND) operated in its nitrosamine-selective mode. The reporting limit for this procedure, evaluated using two independent statistically unbiased protocols, is 2 ng of NDMA/L, A related procedure, employing an automatic sampler instead of the short-path thermal desorber, provides convenient analysis of heavily contaminated samples and exhibits a reporting limit (same protocols cited previously) of 110 ng of NDMA/L. When the two methods are used together in a ''two-tiered'' protocol, NDMA concentrations spanning 4 orders of magnitude (ng/L to mu g/L levels) may be measured routinely. The low-level procedure employing only the short-path thermal desorber was applied successfully to three sources of drinking water, where NDMA concentrations ranged between 2 and 10 ng of NDMA/L, The two-tiered protocol was applied to a series of contaminated groundwaters whose NDMA concentrations ranged between approximately 10-7000 ng of NDMA/L. The results agreed with those obtained from an independent collaborating laboratory, which used a different analytical procedure.
引用
收藏
页码:4387 / 4395
页数:9
相关论文
共 36 条
[1]  
BRITTEN AJ, 1989, RES DEV, P77
[2]   PRESENCE OF DIMETHYL-NITROSAMINES AND DIETHYL-NITROSAMINES IN DEIONIZED WATER [J].
FIDDLER, W ;
PENSABENE, JW ;
DOERR, RC ;
DOOLEY, CJ .
FOOD AND COSMETICS TOXICOLOGY, 1977, 15 (05) :441-443
[3]   N-NITROSODIMETHYLAMINE IN AIR [J].
FINE, DH ;
ROUNBEHLER, DP ;
PELLIZZARI, ED ;
BUNCH, JE ;
BERKLEY, RW ;
MCCRAE, J ;
BURSEY, JT ;
SAWICKI, E ;
KROST, K ;
DEMARRAIS, GA .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1976, 15 (06) :739-746
[4]   DETERMINATION OF DIMETHYLNITROSAMINE IN AIR, WATER, AND SOIL BY THERMAL-ENERGY ANALYSIS - MEASUREMENTS IN BALTIMORE, MD. [J].
FINE, DH ;
ROUNBEHLER, DP ;
ROUNBEHLER, A ;
SILVERGLEID, A ;
SAWICKI, E ;
KROST, K ;
DEMARRAIS, GA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1977, 11 (06) :581-584
[5]   DESCRIPTION OF THERMAL ENERGY ANALYZER (TEA) FOR TRACE DETERMINATION OF VOLATILE AND NONVOLATILE N-NITROSO COMPOUNDS [J].
FINE, DH ;
RUFEH, F ;
LIEB, D ;
ROUNBEHLER, DP .
ANALYTICAL CHEMISTRY, 1975, 47 (07) :1188-1191
[6]   TRACE ANALYSIS OF VOLATILE N-NITROSO COMPOUNDS BY COMBINED GAS-CHROMATOGRAPHY AND THERMAL ENERGY ANALYSIS [J].
FINE, DH ;
ROUNBEHLER, DP .
JOURNAL OF CHROMATOGRAPHY, 1975, 109 (02) :271-279
[7]   DETERMINATION OF DIMETHYLNITROSAMINE IN AIR AND WATER BY THERMAL-ENERGY ANALYSIS - VALIDATION OF ANALYTICAL PROCEDURES [J].
FINE, DH ;
ROUNBEHLER, DP ;
SAWICKI, E ;
KROST, K .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1977, 11 (06) :577-580
[8]   VOLATILE NITROSAMINES IN FOODS AND BEVERAGES - PRELIMINARY SURVEY OF THE ITALIAN MARKET [J].
GAVINELLI, M ;
FANELLI, R ;
BONFANTI, M ;
DAVOLI, E ;
AIROLDI, L .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1988, 40 (01) :41-46
[9]   VOLATILE NITROSAMINES FROM ION-EXCHANGE RESINS [J].
GOUGH, TA ;
WEBB, KS ;
MCPHAIL, MF .
FOOD AND COSMETICS TOXICOLOGY, 1977, 15 (05) :437-440
[10]  
GREGORY B, 1994, COMMUNICATION