CAPILLARY ZONE ELECTROPHORESIS WITH TIME-RESOLVED FLUORESCENCE DETECTION USING A DIODE-PUMPED SOLID-STATE LASER

被引:23
作者
MILLER, KJ [1 ]
LYTLE, FE [1 ]
机构
[1] PURDUE UNIV,DEPT CHEM,1393 BROWN LABS,W LAFAYETTE,IN 47907
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 648卷 / 01期
基金
美国国家科学基金会;
关键词
D O I
10.1016/0021-9673(93)83307-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrophoresis system with time-resolved fluorescence detection was developed using a diode-pumped solid-state laser. The laser provides 2.5-ns pulses at 349 nm with kHz repetition rates, and the Gaussian-shaped beam can easily be focused to the dimensions of a capillary. The short pulse width makes it possible to achieve nanosecond resolution and time-filtered detection. With this approach, the total signal from one injection can be collected and digitally processed to yield simultaneously ''two-channel'' data. Instrument capability is demonstrated by resolving short-lived fluorescent interferences in biological sample matrixes from long-lived fluorophores.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 27 条
[1]   FLUORESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS [J].
AMANKWA, LN ;
ALBIN, M ;
KUHR, WG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (03) :114-120
[2]   ULTRAMICRO ENZYME ASSAYS IN A CAPILLARY ELECTROPHORETIC SYSTEM [J].
BAO, JM ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :217-224
[3]   SIMPLE TIME-RESOLVED FLUOROMETER BASED ON A NANOSECOND DIGITAL OSCILLOSCOPE AND A DIODE-PUMPED, SOLID-STATE LASER [J].
BASILE, F ;
CARDAMONE, A ;
GRINSTEAD, KD ;
MILLER, KJ ;
LYTLE, FE ;
CAPRARA, A ;
CLARK, CD ;
HERITIER, JM .
APPLIED SPECTROSCOPY, 1993, 47 (02) :207-210
[4]   FLUOROMETRIC DATA-PROCESSING STRATEGIES USING NANOSECOND WAVE-FORM DIGITIZERS [J].
CAMPOS, TL ;
LYTLE, FE .
APPLIED SPECTROSCOPY, 1992, 46 (12) :1859-1865
[5]   TIME-RESOLVED LASER-INDUCED FLUORESCENCE STUDY ON DYES USED IN DNA SEQUENCING [J].
CHANG, KY ;
FORCE, RK .
APPLIED SPECTROSCOPY, 1993, 47 (01) :24-29
[6]   LOW-COST, HIGH-SENSITIVITY LASER-INDUCED FLUORESCENCE DETECTION FOR DNA SEQUENCING BY CAPILLARY GEL-ELECTROPHORESIS [J].
CHEN, DY ;
SWERDLOW, HP ;
HARKE, HR ;
ZHANG, JZ ;
DOVICHI, NJ .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :237-246
[7]   ONLINE FLUORESCENCE LIFETIME DETECTION FOR CHROMATOGRAPHIC PEAK RESOLUTION [J].
COBB, WT ;
MCGOWN, LB .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :186-189
[8]   IDENTIFICATION OF BACTERIAL PATHOGENS BY LASER-EXCITED FLUORESCENCE [J].
COBURN, JT ;
LYTLE, FE ;
HUBER, DM .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1669-1673
[9]   MEASUREMENT OF FLUORESCENCE LIFETIMES DURING LIQUID-CHROMATOGRAPHY [J].
DESILETS, DJ ;
KISSINGER, PT ;
LYTLE, FE .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1830-1834