DETERMINATION OF MINUTE AMOUNTS OF ATP BY FLOW-INJECTION ANALYSIS USING ENZYME AMPLIFICATION REACTIONS AND FLUORESCENCE DETECTION

被引:10
作者
HANSEN, EH
GUNDSTRUP, M
MIKKELSEN, HS
机构
[1] Chemistry Department A, The Technical University of Denmark, Lyngby
关键词
ENZYME AMPLIFICATION; ATP ASSAY; FLOW INJECTION ANALYSIS; FIA; FLUOROMETRY; CO-IMMOBILIZED ENZYMES;
D O I
10.1016/0168-1656(93)90081-W
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A flow-injection system for assay of trace levels of ATP is described that incorporates a small column reactor containing co-immobilized hexokinase, pyruvate kinase and glucose-6-phosphate dehydrogenase. In the presence of appropriate cofactors, ATP is by the synergistic operation of the enzymes repeatedly recycled, resulting in substrate amplification. The ultimately generated NADH is measured fluorometrically. By this approach, where the enzymatic degradation step and the detection step are completely separated, it is possible to operate them individually under optimal conditions. The amplification factor is directly proportional to the residence time of the sample zone within the enzyme reactor, which time might be manipulated by altering the flow-rate and in the extreme by performing stopped-flow experiments. Amplification factors between 15 and 1000 were obtained, but it was found that increased amplifications did not lead to significantly lower detection limits; thus, it appears that a practical lower limit of detection is of the order of 1-5 nM. An investigation of this paradoxical feature, and a possible explanation for it, is given.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 13 条
[1]   EXPLOITATION OF THE FLOW-INJECTION APPROACH FOR ANALYTICAL PROCEDURES BASED ON ENZYMATIC AMPLIFICATION REACTIONS [J].
HANSEN, EH ;
ARNDAL, A ;
NORGAARD, L .
ANALYTICAL LETTERS, 1990, 23 (02) :225-240
[2]   OPTIMIZATION OF FLOW-INJECTION SYSTEMS FOR DETERMINATION OF SUBSTRATES BY MEANS OF ENZYME AMPLIFICATION REACTIONS AND CHEMILUMINESCENCE DETECTION [J].
HANSEN, EH ;
NORGAARD, L ;
PEDERSEN, M .
TALANTA, 1991, 38 (03) :275-282
[3]  
KAYNE FJ, 1973, ENZYMES, V7
[4]   HIGHLY SENSITIVE ENZYME THERMISTOR DETERMINATION OF ADP AND ATP BY MULTIPLE RECYCLING ENZYME-SYSTEMS [J].
KIRSTEIN, D ;
DANIELSSON, B ;
SCHELLER, F ;
MOSBACH, K .
BIOSENSORS, 1989, 4 (04) :231-239
[5]   AN ENZYME ELECTRODE FOR L-LACTATE WITH A CHEMICALLY-AMPLIFIED RESPONSE [J].
MIZUTANI, F ;
YAMANAKA, T ;
TANABE, Y ;
TSUDA, K .
ANALYTICA CHIMICA ACTA, 1985, 177 :153-166
[6]   ENZYMATIC ASSAY BY FLOW-INJECTION ANALYSIS WITH DETECTION BY CHEMILUMINESCENCE - DETERMINATION OF GLUCOSE, CREATININE, FREE-CHOLESTEROL AND LACTIC-ACID USING AN INTEGRATED FIA MICROCONDUIT [J].
PETERSSON, BA ;
HANSEN, EH ;
RUZICKA, J .
ANALYTICAL LETTERS, 1986, 19 (5-6) :649-665
[7]  
Ruzicka J., 1988, FLOW INJECTION ANAL, Vsecond
[8]   ENZYME ELECTRODES AND THEIR APPLICATION [J].
SCHELLER, F ;
KIRSTEIN, D ;
KIRSTEIN, L ;
SCHUBERT, F ;
WOLLENBERGER, U ;
OLSSON, B ;
GORTON, L ;
JOHANSSON, G ;
ALBERRY, WJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) :85-94
[9]   RESEARCH AND DEVELOPMENT OF BIOSENSORS - A REVIEW [J].
SCHELLER, F ;
SCHUBERT, F ;
PFEIFFER, D ;
HINTSCHE, R ;
DRANSFELD, I ;
RENNEBERG, R ;
WOLLENBERGER, U ;
RIEDEL, K ;
PAVLOVA, M ;
KUHN, M ;
MULLER, HG ;
TAN, PM ;
HOFFMANN, W ;
MORITZ, W .
ANALYST, 1989, 114 (06) :653-662
[10]   BIOSENSORS - TRENDS AND COMMERCIALIZATION [J].
SCHELLER, FW ;
SCHUBERT, F ;
RENNEBERG, R ;
MULLER, HG ;
JANCHEN, M ;
WEISE, H .
BIOSENSORS, 1985, 1 (02) :135-160