BANDWIDTH CONTROL OF AN ELECTROSTATIC ULTRASONIC TRANSDUCER

被引:15
作者
MATTILA, P [1 ]
HIETANEN, J [1 ]
机构
[1] UNIV HELSINKI,DEPT PHYS,SF-00014 HELSINKI,FINLAND
关键词
BANDWIDTH CONTROL; ELECTROSTATIC TRANSDUCER; ULTRASONIC TRANSDUCER;
D O I
10.1016/0924-4247(94)00841-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The bandwidth of an electrostatic ultrasonic transducer with a V-grooved backplate has been studied experimentally. The highest correlation is found to be between the bandwidth and the resonance frequency, and this relationship seems to be linear. Analysis indicates that the groove angle has no major effect on the bandwidth. Within certain limits the bandwidth can be increased by using a multiple-sized groove pattern in the backplate. The optimum performance is achieved when two groove sizes are used and the difference between groove sizes is small. In some cases transducers with multiple-sized grooves in the backplate show unpredictable responses.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 13 条
[1]   DIAGNOSTIC MEASUREMENTS IN CAPACITIVE TRANSDUCERS [J].
CARR, H ;
WYKES, C .
ULTRASONICS, 1993, 31 (01) :13-20
[2]  
EVERETT HR, 1985, ROBOTICS AGE JUL, P13
[3]   A MODEL FOR AN ELECTROSTATIC ULTRASONIC TRANSDUCER WITH A GROOVED BACKPLATE [J].
HIETANEN, J ;
STORPELLINEN, J ;
LUUKKALA, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (11) :1095-1097
[4]   A HELMHOLTZ RESONATOR MODEL FOR AN ELECTROSTATIC ULTRASONIC AIR TRANSDUCER WITH A V-GROOVED BACKPLATE [J].
HIETANEN, J ;
STORPELLINEN, J ;
LUUKKALA, M ;
MATTILA, P ;
TSUZUKI, F ;
SASAKI, K .
SENSORS AND ACTUATORS A-PHYSICAL, 1993, 39 (02) :129-132
[5]   FACTORS AFFECTING THE SENSITIVITY OF ELECTROSTATIC ULTRASONIC TRANSDUCERS [J].
HIETANEN, J ;
MATTILA, P ;
STORPELLINEN, J ;
TSUZUKI, F ;
VAATAJA, H ;
SASAKI, K ;
LUUKKALA, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (10) :1138-1142
[6]  
JAFFE DL, 1985, ROBOTIC AGE MAR, P23
[7]  
Kalberer R., 1987, Ultrasonics International 87 Conference Proceedings, P432
[8]  
KLEINSCHMIDT P, 1985, OCT P IEEE ULTR S SA, P457
[9]  
MAGORI V, 1987, IEEE T ULTRASON FERR, P202
[10]   ULTRASONIC TRANSDUCERS AND TRANSDUCER ARRAYS FOR APPLICATIONS IN AIR [J].
MANTHEY, W ;
KROEMER, N ;
MAGORI, V .