CHARACTERIZATION OF MEDIATED AND NON-MEDIATED OXIDASE ENZYME-BASED GLASSY-CARBON ELECTRODES

被引:21
作者
AMINE, A [1 ]
KAUFFMANN, JM [1 ]
PATRIARCHE, GJ [1 ]
CHRISTIAN, GD [1 ]
机构
[1] UNIV WASHINGTON, DEPT CHEM, SEATTLE, WA 98195 USA
关键词
D O I
10.1016/0039-9140(93)80181-P
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance and analytical characteristics of a glassy carbon glutaraldehyde immobilized glucose oxidase electrode have been established with regard to the direct detection of hydrogen peroxide produced from the reaction of glucose with oxygen. Measurements were performed at +1.1 V vs. SCE, and selectivity was obtained by casting the surface with a cellulose acetate membrane. Results compared favorably with the classical platinum-enzyme probe. The mechanism of ascorbic acid interference in hydrogen peroxide detection is reported. Mediated detection was also investigated for oxidase enzymes (glucose oxidase and xanthine oxidase) immobilized on the bare glassy carbon electrode. The probes were characterized using a specific enzyme mediator in solution (phenazine methosulfate or dichlorophenol-indophenol) plus hexacyanoferrate(III) as an electrochemical mediator. The electrode was poised at + 0.36 V vs. SCE for the detection of hexacyanoferrate(II). The advantages of this dual mediator configuration include high stability and sensitivity of the electrochemical signal and the ability to use less positive potentials for increased selectivity. Application to other enzymes, such as hydrogenases, using such a binary redox configuration is suggested.
引用
收藏
页码:1157 / 1162
页数:6
相关论文
共 35 条
[21]  
KULYS JJ, 1983, BIOCHIM BIOPHYS ACTA, V744, P57, DOI 10.1016/0167-4838(83)90340-0
[22]   HOMOGENEOUS MECHANISM OF ASCORBIC-ACID INTERFERENCE IN HYDROGEN-PEROXIDE DETECTION AT ENZYME-MODIFIED ELECTRODES [J].
LOWRY, JP ;
ONEILL, RD .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :453-456
[23]  
MAGUIRE GA, 1983, CLIN CHEM, V29, P1810
[24]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[25]   GRAPHITE PASTE-BASED ENZYMATIC GLUCOSE ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
MATUSZEWSKI, W ;
TROJANOWICZ, M .
ANALYST, 1988, 113 (05) :735-738
[26]   A STUDY OF INTERFERENCES IN GLUCOSE MEASUREMENTS IN BLOOD BY HYDROGEN-PEROXIDE BASED GLUCOSE PROBES [J].
PALLESCHI, G ;
RAHNI, MAN ;
LUBRANO, GJ ;
NGWAINBI, JN ;
GUILBAULT, GG .
ANALYTICAL BIOCHEMISTRY, 1986, 159 (01) :114-121
[27]  
PEEL JL, 1972, METHODS MICROBIOLO B, V6
[28]   BIOSENSOR FOR LACTATE DETERMINATION IN BIOLOGICAL-FLUIDS .2. INTERFERENCE STUDIES [J].
RACEK, J ;
MUSIL, J .
CLINICA CHIMICA ACTA, 1987, 167 (01) :59-65
[29]   BIOSENSOR FOR LACTATE DETERMINATION IN BIOLOGICAL-FLUIDS .1. CONSTRUCTION AND PROPERTIES OF THE BIOSENSOR [J].
RACEK, J ;
MUSIL, J .
CLINICA CHIMICA ACTA, 1987, 162 (02) :129-139
[30]   ACTIVITY OF CHOLINE OXIDASE MONITORED INSITU WITH AN UNMODIFIED GLASSY-CARBON ELECTRODE [J].
STEMPLE, JZ ;
RUSIN, KM ;
FARE, TL .
ANALYTICAL CHEMISTRY, 1991, 63 (10) :1050-1052