FABRICATION OF HIGH-FREQUENCY SPHERICALLY SHAPED CERAMIC TRANSDUCERS

被引:106
作者
LOCKWOOD, GR
TURNBULL, DH
FOSTER, FS
机构
[1] SUNNYBROOK HLTH SCI CTR,TORONTO M4N 3M5,ON,CANADA
[2] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M5S 1A1,ONTARIO,CANADA
关键词
D O I
10.1109/58.279136
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Difficulty in obtaining well focused efficient ultrasound transducers has limited the development of new high frequency applications of B-mode imaging. This paper describes a method for fabricating high frequency (53 MHz) spherically focused lead zirconate titanate (PZT) transducers. A transducer is fabricated by bonding a malleable backing layer onto a thin plate of PZT and then pressing the plate into a spherically shaped well. The backing layer evenly distributes stresses across the material when it is pressed into the well. Local concentrations of stress which lead to fracture are avoided and the material can be deformed without macroscopic cracking. The characteristics of a 2 mm diameter 53 MHz PZT transducer with a 4 mm focal length are described. A lateral beam width of 68 mum and a 12 dB depth of field of 1.5 mm were obtained. The minimum two-way insertion loss of the system was -25 dB and the 6 dB bandwidth of the pulse echo response was 30%. An image of a resolution phantom and an in vivo skin image illustrate the excellent imaging characteristics of the transducer.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 14 条
[1]   HIGH-RESOLUTION REAL-TIME ULTRASONIC SCANNER [J].
BERSON, M ;
VAILLANT, L ;
PATAT, F ;
POURCELOT, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (05) :471-478
[2]   CHARACTERIZATION OF LEAD ZIRCONATE TITANATE CERAMICS FOR USE IN MINIATURE HIGH-FREQUENCY (20-80 MHZ) TRANSDUCERS [J].
FOSTER, FS ;
RYAN, LK ;
TURNBULL, DH .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (05) :446-453
[3]  
FOSTER FS, IN PRESS IEEE T ULTR
[4]  
HARTLEY CJ, 1988, SPIE MICROSENSORS CA, V904, P103
[5]  
LIZZI FL, 1992, P SOC PHOTO-OPT INS, V1733, P313, DOI 10.1117/12.130610
[6]   A 45 TO 55 MHZ NEEDLE-BASED ULTRASOUND SYSTEM FOR INVASIVE IMAGING [J].
LOCKWOOD, GR ;
RYAN, LK ;
FOSTER, FS .
ULTRASONIC IMAGING, 1993, 15 (01) :1-13
[7]   MODELING AND OPTIMIZATION OF HIGH-FREQUENCY ULTRASOUND TRANSDUCERS [J].
LOCKWOOD, GR ;
FOSTER, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (02) :225-230
[8]   A 20-MHZ ULTRASOUND SYSTEM FOR IMAGING THE INTESTINAL WALL [J].
MARTIN, RW ;
SILVERSTEIN, FE ;
KIMMEY, MB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (03) :273-280
[9]   FEASIBILITY OF HIGH-RESOLUTION, INTRAVASCULAR ULTRASONIC-IMAGING CATHETERS [J].
MEYER, CR ;
CHIANG, EH ;
FECHNER, KP ;
FITTING, DW ;
WILLIAMS, DM ;
BUDA, AJ .
RADIOLOGY, 1988, 168 (01) :113-116
[10]  
PAVLIN CJ, 1990, OPHTHALMOLOGY, V97, P244