INDUSTRIAL NOISE EXPOSURE AND AMBULATORY BLOOD-PRESSURE AND HEART-RATE

被引:28
作者
GREEN, MS
SCHWARTZ, K
HARARI, G
NAJENSON, T
机构
[1] Cardiovascular Epidemiology Unit, Occupational Health and Rehabilitation Institute, Raanana
关键词
D O I
10.1097/00043764-199108000-00013
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Studies on the effects of long-term exposure to industrial noise on resting blood pressure have yielded inconsistent results. Ambulatory blood pressure and heart rate were monitored simultaneously with noise exposure in normotensive male industrial workers in Israel (85 aged 25 to 44 and 77 aged 45 to 65 years). In the younger group, average ambulatory systolic blood pressure was 3.2 mm Hg higher and diastolic blood pressure 2.3 mm Hg higher in subjects exposed to more than 85 dBa (P < .001), after adjusting for potential confounding variables. In those aged 45 to 65, ambulatory systolic blood pressure was 3.3 mm Hg lower and diastolic blood pressure unchanged in noise-exposed subjects. Ambulatory heart rate was 2.7 and 2.6 beats per minute higher at the higher noise level (P = .002) in the respective age groups. These findings suggest that industrial noise exposure is associated with higher ambulatory blood pressure and heart rates in men under 45 years old, but the effect on blood pressure appears to diminish considerably with age.
引用
收藏
页码:879 / 883
页数:5
相关论文
共 22 条
[11]   MODIFICATIONS OF EPINEPHRINE, NOREPINEPHRINE, BLOOD LIPID FRACTIONS AND CARDIOVASCULAR-SYSTEM PRODUCED BY NOISE IN AN INDUSTRIAL MEDIUM [J].
ORTIZ, GA ;
ARGUELLES, AE ;
CRESPIN, HA ;
SPOSARI, G ;
VILLAFANE, CT .
HORMONE RESEARCH, 1974, 5 (01) :57-64
[12]   RELATIONSHIP OF 24-HOUR BLOOD-PRESSURE MEAN AND VARIABILITY TO SEVERITY OF TARGET-ORGAN DAMAGE IN HYPERTENSION [J].
PARATI, G ;
POMIDOSSI, G ;
ALBINI, F ;
MALASPINA, D ;
MANCIA, G .
JOURNAL OF HYPERTENSION, 1987, 5 (01) :93-98
[13]   THE PROGNOSTIC VALUE OF AMBULATORY BLOOD PRESSURES [J].
PERLOFF, D ;
SOKOLOW, M ;
COWAN, R .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 249 (20) :2792-2798
[14]   NONINVASIVE AMBULATORY BLOOD-PRESSURE MONITORING IN PATIENTS WITH RECENTLY DETECTED SYSTEMIC HYPERTENSION [J].
PHILLIPS, RA ;
GOLDMAN, ME ;
EISON, HB ;
KRAKOFF, LR .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (11) :F62-F64
[15]   AMBULATORY MONITORING OF BLOOD-PRESSURE AS A PREDICTOR OF CARDIOVASCULAR RISK [J].
PICKERING, TG ;
DEVEREUX, RB .
AMERICAN HEART JOURNAL, 1987, 114 (04) :925-928
[16]   EXERCISE CARDIAC-OUTPUT IS MAINTAINED WITH ADVANCING AGE IN HEALTHY-HUMAN SUBJECTS - CARDIAC DILATATION AND INCREASED STROKE VOLUME COMPENSATE FOR A DIMINISHED HEART-RATE [J].
RODEHEFFER, RJ ;
GERSTENBLITH, G ;
BECKER, LC ;
FLEG, JL ;
WEISFELDT, ML ;
LAKATTA, EG .
CIRCULATION, 1984, 69 (02) :203-213
[17]  
ROWLANDS DB, 1981, CLIN SCI, V61, P101
[18]  
SOKOLOW M, 1966, CIRCULATION, V34, P279
[19]   OCCUPATIONAL NOISE EXPOSURE, NOISE-INDUCED HEARING-LOSS, AND THE EPIDEMIOLOGY OF HIGH BLOOD-PRESSURE [J].
TALBOTT, E ;
HELMKAMP, J ;
MATTHEWS, K ;
KULLER, L ;
COTTINGTON, E ;
REDMOND, G .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1985, 121 (04) :501-514
[20]  
VERBEEK J H A M, 1987, International Archives of Occupational and Environmental Health, V59, P51, DOI 10.1007/BF00377678