STABILIZATION OF THE SHORT SAGITTAL SPLIT OSTEOTOMY - IN-VITRO TESTING OF DIFFERENT PLATE AND SCREW CONFIGURATIONS

被引:37
作者
HAMMER, B [1 ]
ETTLIN, D [1 ]
RAHN, B [1 ]
PREIN, J [1 ]
机构
[1] AO ASIF RES INST, DAVOS, SWITZERLAND
关键词
D O I
10.1016/S1010-5182(05)80164-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Using a 3-dimensional in vitro model, the stability of different types of osteosynthesis for the short sagittal osteotomy was tested. The following four groups of plate and screw configurations were evaluated: Group I: Fixation with miniplates using monocortical screws only Group II: Fixation with miniplates, but with two of the screws engaging both fragments Group III: Same as group II with an additional position screw Group IV: Fixation with 3 position screws. The stability obtained with miniplate fixation using monocortical screws only (group I) was by a factor of 2.9 less than position screw fixation (group IV), which is considered to be an approved standard. In order to increase the stability of miniplate fixation, the screws in the area of overlapping bone should engage both fragments.
引用
收藏
页码:321 / 324
页数:4
相关论文
共 14 条
[11]  
RAHN BA, 1989, CLIN PLAST SURG, V16, P21
[12]   SKELETAL STABILITY FOLLOWING SAGITTAL SPLIT OSTEOTOMY USING MONOCORTICAL MINIPLATE INTERNAL-FIXATION [J].
RUBENS, BC ;
STOELINGA, PJW ;
BLIJDORP, PA ;
SCHOENAERS, JHA ;
POLITIS, C .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 17 (06) :371-376
[13]   SAGITTAL SPLIT ADVANCEMENT OSTEOTOMIES STABILIZED WITH MINIPLATES - A 2-5-YEAR FOLLOW-UP [J].
SCHEERLINCK, JPO ;
STOELINGA, PJW ;
BLIJDORP, PA ;
BROUNS, JJA ;
NIJS, MLL .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 23 (03) :127-131
[14]  
Spiessl B, 1974, Fortschr Kiefer Gesichtschir, V18, P145