SOFTWARE FOR ILLUSTRATIVE PRESENTATION OF BASIC CLINICAL CHARACTERISTICS OF LABORATORY TESTS - GRAPHROC FOR WINDOWS

被引:150
作者
KAIRISTO, V [1 ]
POOLA, A [1 ]
机构
[1] UNIV TURKU,DEPT CLIN CHEM,TURKU,FINLAND
关键词
CLINICAL DECISION MAKING; DISTRIBUTION FREQUENCIES; HOSPITAL DATA; REFERENCE CHANGE; REFERENCE VALUES;
D O I
10.3109/00365519509088450
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
GraphROC for Windows is a program for clinical test evaluation. It was designed for the handing of large datasets obtained from clinical laboratory databases. In the user interface, graphical and numerical presentations are combined. For simplicity, numerical data is not shown unless requested. Relevant numbers can be ''picked up'' from the graph by simple mouse operations. Reference distributions can be displayed by using automatically optimized bin widths. Any percentile of the distribution with corresponding confidence limits can be chosen for display. In sensitivity-specificity analysis, both illness- and hearth-related distributions are shown in the same graph. The following data for any cutoff limit can be shown in a separate click window: clinical sensitivity and specificity with corresponding confidence limits, positive and negative likelihood ratios, positive and negative predictive values and efficiency. Predictive values and clinical efficiency of the cutoff limit can be updated for any prior probability of disease. Receiver Operating Characteristics (ROC) curves can be generated and combined into the same graph for comparison of several different tests. The area under the curve with corresponding confidence interval is calculated for each ROC curve. Numerical results of analyses and graphs can be printed or exported to other Microsoft Windows programs. GraphROC for Windows also employs a new method, developed by us, for the indirect estimation of health-related limits and change limits from mixed distributions of clinical laboratory data.
引用
收藏
页码:43 / 60
页数:18
相关论文
共 32 条
  • [11] GINDLER EM, 1970, CLIN CHEM, V16, P124
  • [12] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [13] HOFFMANN R G, 1964, GP, V30, P112
  • [14] International Federation of Clinical Chemistry Scientific Committee Clinical Section Expert Panel on Theory of Reference Values and International Committee for Standardization in Haematology, 1987, J CLIN CHEM CLIN BIO, V25, P645
  • [15] KAIRISTO V, 1993, CLIN CHEM, V39, P2298
  • [16] KAIRISTO V, 1994, EUR J CLIN CHEM CLIN, V32, P789
  • [17] KAIRISTO V, GRAPHROC WINDOWS PRO
  • [18] KOURI T, 1994, CLIN CHEM, V40, P2209
  • [19] NANTO V, 1992, SCAND J CLIN LA S211, V52, P39
  • [20] NAUS AJ, 1980, J CLIN CHEM CLIN BIO, V18, P621