ABSORPTION-SPECTRA AND MULTICAPILLARY IMAGING DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING USING A CHARGE-COUPLED-DEVICE CAMERA

被引:39
作者
WU, JQ [1 ]
PAWLISZYN, J [1 ]
机构
[1] UNIV WATERLOO,DEPT CHEM,WATERLOO,ON N2L 3G1,CANADA
关键词
ABSORPTION IMAGING DETECTION; CAPILLARY ISOELECTRIC FOCUSING; CAPILLARY ARRAY; ABSORPTION SPECTRA; CHARGE COUPLED DEVICE CAMERA;
D O I
10.1039/an9952001567
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two absorption imaging detectors using charge coupled device (CCD) cameras are designed for capillary isoelectric focusing (CIEF), In the first detector, a light beam passes through a 4 cm capillary and is dispersed by a grating onto a CCD camera, The two-dimensional CCD in the camera records the light absorption at different positions along the capillary in one dimension, and at different wavelengths in the second dimension, simultaneously. The resolution in wavelength is about 1 nm. Since the separation time in the 4 cm long capillary column is only 4 min, the complete analysis takes 4 min, which is much faster than conventional CIEF methods. In the second detector, a light beam passes through a capillary array and then onto a CCD camera, Isoelectric focusing separation and detection of several samples can be completed in about 4 min, and the focusing processes in all capillaries can be observed simultaneously by the real-time, on-line imaging detector. In both detectors, images are normalized by light intensity, recorded simultaneously with the images, to compensate for intensity fluctuation of the light source, The detection limit of the detector is 1.5 X 10(-3) absorbance units. The pH resolution of the instrument with the 4 cm long capillaries is 0.01 which is the same or better than that of conventional CIEF instruments with much longer capillaries, The deviation in pH of replicate zone positions in different capillaries of the capillary array is less than 0.01 which is much better than capillary array IEF methods using the mobilization process.
引用
收藏
页码:1567 / 1571
页数:5
相关论文
共 13 条
[1]   CHARACTERIZATION OF HUMANIZED ANTI-TAC MONOCLONAL-ANTIBODY BY TRADITIONAL SEPARATION TECHNIQUES AND CAPILLARY ELECTROPHORESIS [J].
COSTELLO, MA ;
WOITITZ, C ;
DEFEO, J ;
STREMLO, D ;
WEN, LFL ;
PALLING, DJ ;
IQBAL, K ;
GUZMAN, NA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1081-1097
[2]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[3]   DETERMINATION OF PI BY MEASURING THE CURRENT IN THE MOBILIZATION STEP OF HIGH-PERFORMANCE CAPILLARY ISOELECTRIC-FOCUSING - ANALYSIS OF TRANSFERRIN FORMS [J].
KILAR, F .
JOURNAL OF CHROMATOGRAPHY, 1991, 545 (02) :403-406
[4]   APPLICATION OF DYNAMIC CAPILLARY ISOELECTRIC-FOCUSING TO THE ANALYSIS OF HUMAN HEMOGLOBIN-VARIANTS [J].
MOLTENI, S ;
FRISCHKNECHT, H ;
THORMANN, W .
ELECTROPHORESIS, 1994, 15 (01) :22-30
[5]  
Righetti P. G., 1983, ISOELECTRIC FOCUSING
[6]   DUAL DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING WITH REFRACTIVE-INDEX GRADIENT AND ABSORPTION IMAGING DETECTORS [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :867-873
[7]   UNIVERSAL DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING WITHOUT MOBILIZATION USING A CONCENTRATION GRADIENT IMAGING-SYSTEM [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :224-227
[8]   IN-VITRO OBSERVATION OF INTERACTIONS OF IRON AND TRANSFERRIN BY CAPILLARY ISOELECTRIC-FOCUSING WITH A CONCENTRATION GRADIENT IMAGING DETECTION SYSTEM [J].
WU, JQ ;
PAWLISZYN, J .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :295-299
[9]   CAPILLARY ISOELECTRIC-FOCUSING WITH IMAGING DETECTION [J].
WU, JQ ;
PAWLISZYN, J .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10) :1891-1902
[10]   CAPILLARY ISOELECTRIC-FOCUSING WITH A UNIVERSAL CONCENTRATION GRADIENT IMAGING-SYSTEM USING A CHARGE-COUPLED PHOTODIODE ARRAY [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :2934-2941