LOW-PRESSURE GAS-CHROMATOGRAPHY WITH SPLIT INJECTION AND PHOTOIONIZATION DETECTION

被引:15
作者
PUIG, L [1 ]
SACKS, RD [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
D O I
10.1093/chromsci/29.4.158
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The advantages of low-pressure gas chromatography (GC) are discussed. The performance of a commercial photoinization detector (PID) operated at subambient pressure is evaluated using a GC system designed for high speed, vacuum outlet operation. At atmospheric pressure, use of the PID results in significant band broadening relative to a flame ionization detector (FID) for elution times of a few seconds. Even with the use of 50mL/min makeup gas, excessive band broadening occurs with the PID. At a pressure of 10 Torr, use of the PID results in no significant band broadening, and greater resolution is achieved than with the FID operated atmospheric pressure for similar retention times. Chromatograms are presented showing the effects of outlet pressure and makeup gas flow on PID performance.
引用
收藏
页码:158 / 164
页数:7
相关论文
共 28 条
[11]  
Golay MJE, 1958, GAS CHROMATOGRAPHY
[12]   THEORETICAL AND PRACTICAL ASPECTS OF SHORT OPEN TUBULAR COLUMNS AT SUBAMBIENT PRESSURES IN GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HAIL, ME ;
YOST, RA .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2402-2410
[13]   VACUUM GAS-CHROMATOGRAPHY USING SHORT GLASS CAPILLARY COLUMNS COMBINED WITH MASS-SPECTROMETRY [J].
HATCH, FW ;
PARRISH, ME .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1164-1168
[14]  
INGRAHAM D, 1981, HRC-J HIGH RES CHROM, V5, P227
[15]   GAS-LIQUID PARTITION CHROMATOGRAPHY - THE SEPARATION AND MICRO-ESTIMATON OF VOLATILE FATTY ACIDS FROM FORMIC ACID TO DODECANOIC ACID [J].
JAMES, AT ;
MARTIN, AJP .
BIOCHEMICAL JOURNAL, 1952, 50 (05) :679-690
[16]   DIFFUSION IN SILICONE STATIONARY PHASES [J].
KONG, JM ;
HAWKES, SJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1976, 14 (06) :279-287
[17]   MINIMUM ANALYSIS TIME IN CAPILLARY GAS-CHROMATOGRAPHY - VACUUM-OUTLET VERSUS ATMOSPHERIC-OUTLET COLUMN OPERATION [J].
LECLERCQ, PA ;
CRAMERS, CA .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :269-272
[18]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY SYSTEMS .2. ADVANTAGES OF VACUUM OUTLET OPERATION OF THICK-FILM CAPILLARY COLUMNS [J].
LECLERCQ, PA ;
SCHERPENZEEL, GJ ;
VERMEER, EAA ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1982, 241 (01) :61-71
[19]   IONIZATION METHODS FOR ANALYSIS OF GASES AND VAPORS [J].
LOVELOCK, JE .
ANALYTICAL CHEMISTRY, 1961, 33 (02) :162-&
[20]  
MILLEN W, 1977, J CHROMATOGR SCI, V15, P148