DETERMINATION OF PERTECHNETATE IN RADIOPHARMACEUTICALS BY HIGH-PRESSURE LIQUID, THIN-LAYER AND PAPER-CHROMATOGRAPHY

被引:15
作者
RUSSELL, CD
MAJERIK, JE
机构
[1] VET ADM HOSP,MED CTR,DEPT DIAGNOST RADIOL,BIRMINGHAM,AL 35233
[2] UNIV ALABAMA,MED CTR,BIRMINGHAM,AL 35233
来源
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES | 1979年 / 30卷 / 12期
关键词
D O I
10.1016/0020-708X(79)90155-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Pertevhnetate ion, considered a common impurity, is usually determined in technetium pharmaceuticals by paper or thin-layer chromotography. The results are often sensitive to variations in procedure, particularly with relatively unstable agents such as pyrophosphate. We have developed a method for determining partechnetate by high pressure liquid chromatography (HPLC) and compared it with previous methods, which include a commercially available kit. When applied to a variety of agents in clinical use (technetium pyrophosphate, methylene diphosphonate, glucoheptonate, diethylenetriaminepentaacetate) HPLC indicated lower concentrations of pertechnetate than did conventional methods. In fact, though pertechnetate was demonstrated in tin-free electrolytic preparations or in tin-labelled preparations' which had been exposed to air, HPLC showed no pertechnetate in fresh preparations containing excess tin. We conclude that: (1) the reaction of Sn(II)with pertechnetate is rapid enough under usual labelling conditions that the two species do not coexist, (2) when pertechnetate is found in preparation containing excess Sn(II) it is usually an artifact of the chromatographic procedure, (3) by careful choice of paper or thin-layer method (which must be verified for each formulation) this artifact can often be rendered neglible and (4) HPLC is useful as a reference method for determining pertechnetate in radiopharmaceuticals. © 1979.
引用
收藏
页码:753 / 756
页数:4
相关论文
共 15 条
[1]  
BILLINGHURST MW, 1973, J NUCL MED, V14, P793
[2]  
DEUTSCH EA, 1978, OCT WEST REG M SOC N
[3]   RADIOPHARMACEUTICALS LABELED WITH TECHNETIUM [J].
ECKELMAN, WC ;
LEVENSON, SM .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1977, 28 (1-2) :67-82
[4]  
ECKELMAN WC, 1972, J NUCL MED, V13, P202
[5]  
ECKELMAN WC, 1977, APPL RADIOL NUCL MED, V6, P211
[6]  
FIELDS AT, 1978, J NUCL MED, V19, P694
[7]   CHEMICAL AND BIOLOGICAL STUDIES ON TC-99M-DMS .2. EFFECT OF SN(II) ON FORMATION OF VARIOUS TC-DMS COMPLEXES [J].
IKEDA, I ;
INOUE, O ;
KURATA, K .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (12) :681-688
[8]  
JANSHOLT AL, 1978, J NUCL MED, V19, P1036
[9]   TRACER ELECTROCHEMISTRY OF PERTECHNETATE - CHELATION OF TC-99M BY EDTA AFTER CONTROLLED-POTENTIAL REDUCTION AT MERCURY AND PLATINUM CATHODES [J].
RUSSELL, CD ;
MAJERIK, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (02) :109-114
[10]   OXIDATION-STATE OF TECHNETIUM IN BONE SCANNING AGENTS AS DETERMINED AT CARRIER CONCENTRATION BY AMPEROMETRIC-TITRATION [J].
RUSSELL, CD ;
CASH, AG .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1979, 30 (08) :485-488